← Illinois

Tap water quality report

Jacksonville

EPA monitoring tested this supplier for 109 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
24
detected
19,903
people served
4
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Morgan

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
33
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2011-05-01 → 2011-05-31
MCL Health-based Resolved 2011-05-01 → 2011-05-31
MCL Health-based Resolved 2011-05-01 → 2011-05-31
MCL Health-based Resolved 2011-05-01 → 2011-05-31
Other Monitoring Resolved 2011-07-16
Other Monitoring Resolved 2011-07-16
MR Monitoring Resolved 2011-06-01 → 2011-06-30
MR Monitoring Resolved 2011-06-01 → 2011-06-30
MR Monitoring Resolved 2011-06-01 → 2011-06-30
MR Monitoring Resolved 2011-06-01 → 2011-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0098 µg/L 4/4 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
22.7475 µg/L
No EPA limit set
worst single sample: 24.5 µg/L
128/128 SYR4 2012–2019
Chloroform
45.2495 µg/L
No EPA limit set
worst single sample: 66.1 µg/L
128/128 SYR4 2012–2019
Dibromochloromethane
14.39 µg/L
No EPA limit set
worst single sample: 15.9 µg/L
128/128 SYR4 2012–2019
TTHM
80.895 µg/L 101%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 97.4 µg/L
128/128 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
25.195 µg/L 42%
of the EPA limit 60 µg/L
worst single sample: 28.6 µg/L
128/128 SYR4 2012–2019
Bromoform
3.41 µg/L
No EPA limit set
worst single sample: 4.4 µg/L
126/128 SYR4 2012–2019
Dibromoacetic Acid
4.935 µg/L
No EPA limit set
worst single sample: 5.9 µg/L
126/128 SYR4 2012–2019
Dichloroacetic Acid
14 µg/L
No EPA limit set
worst single sample: 17.5 µg/L
124/128 SYR4 2012–2019
Trichloroacetic Acid
7.1215 µg/L
No EPA limit set
worst single sample: 8.9 µg/L
112/128 SYR4 2012–2019
Nitrate
1895 µg/L 19%
of the EPA limit 10000 µg/L
worst single sample: 1900 µg/L
22/28 SYR4 2012–2019
Copper
7.5 µg/L 0.6%
of the EPA limit 1300 µg/L
worst single sample: 19 µg/L
21/60 SYR4 2014–2017
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
21/21 LCR 2025
Barium
127 µg/L 6.4%
of the EPA limit 2000 µg/L
worst single sample: 140 µg/L
14/14 SYR4 2012–2019
Monobromoacetic Acid
4.5305 µg/L
No EPA limit set
worst single sample: 4.55 µg/L
14/128 SYR4 2012–2019
Fluoride
909 µg/L 23%
of the EPA limit 4000 µg/L
worst single sample: 915 µg/L
9/14 SYR4 2012–2019
Arsenic
8.525 µg/L 85%
of the EPA limit 10 µg/L
worst single sample: 9.4 µg/L
8/14 SYR4 2012–2019
Lead
2.25 µg/L 15%
of the EPA limit 15 µg/L
worst single sample: 2.3 µg/L
6/60 SYR4 2014–2017
Nitrate-Nitrite
1375 µg/L 14%
of the EPA limit 10000 µg/L
worst single sample: 1400 µg/L
6/9 SYR4 2012–2019
Combined Radium (-226 And -228)
1.7772 pCi/L 36%
of the EPA limit 5 pCi/L
worst single sample: 1.778 pCi/L
3/3 SYR4 2014–2017
Monochloroacetic Acid
3.173 µg/L
No EPA limit set
worst single sample: 3.21 µg/L
3/128 SYR4 2012–2019
Selenium
3.075 µg/L 6.2%
of the EPA limit 50 µg/L
worst single sample: 3.1 µg/L
2/14 SYR4 2012–2019
Chromium
5.4 µg/L 5.4%
of the EPA limit 100 µg/L
1/14 SYR4 2012–2019
Pentachlorophenol
0.7200 µg/L 72%
of the EPA limit 1 µg/L
1/18 SYR4 2012–2019
85 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HEARIN, RICKY
Phone
217-479-4660
Email
[email protected]

Frequently asked questions about Jacksonville

Is Jacksonville tap water safe to drink?

EPA monitoring detected 24 contaminants in Jacksonville's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Jacksonville's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Jacksonville serve?

Jacksonville reports serving 19,903 people in Illinois, per its EPA record.

Has Jacksonville had any water quality violations?

The EPA has 33 violations on file for Jacksonville, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.