Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| Other | Monitoring | Resolved | 2024-04-11 |
| Other | Monitoring | Resolved | 2024-04-11 |
| MR | Monitoring | Resolved | 2023-10-01 → 2023-12-31 |
| MR | Monitoring | Resolved | 2023-10-01 → 2023-12-31 |
| MR | Monitoring | Resolved | 2023-10-01 → 2023-12-31 |
| MR | Monitoring | Resolved | 2023-10-01 → 2023-12-31 |
| MR | Monitoring | Resolved | 2023-10-01 |
| MR | Monitoring | Resolved | 2023-10-01 |
| MR | Monitoring | Resolved | 2023-10-01 |
| MR | Monitoring | Resolved | 2023-10-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 11000 µg/L 110% of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 12000 µg/L | 142/146 | SYR4 | 2012–2019 |
| Copper | 63.6 µg/L 4.9% of the EPA limit 1300 µg/L
worst single sample: 180 µg/L | 72/80 | SYR4 | 2012–2017 |
| Bromodichloromethane | 19.025 µg/L No EPA limit set
worst single sample: 22.34 µg/L | 46/46 | SYR4 | 2012–2019 |
| Chloroform | 32.185 µg/L No EPA limit set
worst single sample: 38.09 µg/L | 46/46 | SYR4 | 2012–2019 |
| Dibromochloromethane | 23.4425 µg/L No EPA limit set
worst single sample: 26.7 µg/L | 46/46 | SYR4 | 2012–2019 |
| TTHM | 80.675 µg/L 101% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 105 µg/L | 46/46 | SYR4 | 2012–2019 |
| Bromoform | 23.36 µg/L No EPA limit set
worst single sample: 39.6 µg/L | 43/46 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 23.66 µg/L 39% of the EPA limit 60 µg/L
worst single sample: 27.3 µg/L | 43/46 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 7.35 µg/L No EPA limit set
worst single sample: 8.7 µg/L | 41/46 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 15.55 µg/L No EPA limit set
worst single sample: 18.4 µg/L | 35/46 | SYR4 | 2012–2019 |
| Lead | 15.75 µg/L 105% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 130 µg/L | 26/80 | SYR4 | 2012–2017 |
| Trichloroacetic Acid | 11.9 µg/L No EPA limit set
worst single sample: 13.4 µg/L | 21/46 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 19/19 | LCR | 2025 |
| Nitrate-Nitrite | 7700 µg/L 77% of the EPA limit 10000 µg/L | 8/8 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 1.683 µg/L No EPA limit set
worst single sample: 1.71 µg/L | 7/46 | SYR4 | 2012–2019 |
| Barium | 4.85 µg/L 0.2% of the EPA limit 2000 µg/L
worst single sample: 4.9 µg/L | 3/3 | SYR4 | 2012–2018 |
| Fluoride | 940.7 µg/L 24% of the EPA limit 4000 µg/L
worst single sample: 953 µg/L | 3/3 | SYR4 | 2012–2018 |
| Arsenic | 1.4 µg/L 14% of the EPA limit 10 µg/L | 1/3 | SYR4 | 2012–2018 |
| Combined Radium (-226 And -228) | 1.46 pCi/L 29% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2014 |
| Selenium | 2.3 µg/L 4.6% of the EPA limit 50 µg/L | 1/3 | SYR4 | 2012–2018 |
88 contaminants tested, none detected
Utility contact
Frequently asked questions about Athens
Is Athens tap water safe to drink?
EPA monitoring detected 20 contaminants in Athens's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Athens's water?
EPA monitoring detected Nitrate, Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Athens serve?
Athens reports serving 4,575 people in Illinois, per its EPA record.
Has Athens had any water quality violations?
The EPA has 117 violations on file for Athens, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.