Tap water quality report

Lake Villa

EPA monitoring tested this supplier for 44 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
13
detected
8,829
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Lake

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
69
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2023-10-01 → 2023-12-31
MR Monitoring Resolved 2002-04-01 → 2002-06-30
MR Monitoring Resolved 2002-04-01 → 2002-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
647.45 µg/L 50%
of the EPA limit 1300 µg/L
worst single sample: 1320 µg/L
194/220 SYR4 2012–2019
Lead
0.0026 mg/L 17%
of the EPA limit 0.0150 mg/L
25/25 LCR 2025
Lead
35.86 µg/L 239%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 53.6 µg/L
23/220 SYR4 2012–2019
Chloroform
16.055 µg/L
No EPA limit set
worst single sample: 16.9 µg/L
14/14 SYR4 2013–2019
TTHM
32.025 µg/L 40%
of the EPA limit 80 µg/L
worst single sample: 33 µg/L
14/14 SYR4 2013–2019
Bromodichloromethane
9.0475 µg/L
No EPA limit set
worst single sample: 9.16 µg/L
10/14 SYR4 2013–2019
Bromoform
1.2575 µg/L
No EPA limit set
worst single sample: 1.26 µg/L
6/14 SYR4 2013–2019
Dibromochloromethane
5.9175 µg/L
No EPA limit set
worst single sample: 5.92 µg/L
6/14 SYR4 2013–2019
Dichloroacetic Acid
6.5 µg/L
No EPA limit set
worst single sample: 7.13 µg/L
6/14 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
11.375 µg/L 19%
of the EPA limit 60 µg/L
worst single sample: 12.6 µg/L
6/14 SYR4 2013–2019
Dibromoacetic Acid
1.546 µg/L
No EPA limit set
worst single sample: 1.55 µg/L
5/14 SYR4 2013–2019
Trichloroacetic Acid
3.11 µg/L
No EPA limit set
worst single sample: 3.2 µg/L
5/14 SYR4 2013–2019
Monobromoacetic Acid
1.5515 µg/L
No EPA limit set
worst single sample: 1.56 µg/L
2/14 SYR4 2013–2019
31 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaMonochloroacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaLithium

Frequently asked questions about Lake Villa

Is Lake Villa tap water safe to drink?

EPA monitoring detected 13 contaminants in Lake Villa's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lake Villa's water?

EPA monitoring detected Copper, Lead, Lead, Chloroform, TTHM, and others. The full list with the level and data source for each is above.

How many people does Lake Villa serve?

Lake Villa reports serving 8,829 people, per its EPA record.

Has Lake Villa had any water quality violations?

The EPA has 69 violations on file for Lake Villa, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.