← Illinois

Tap water quality report

Wienen Estates

EPA monitoring tested this supplier for 78 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
12
detected
95
people served
9
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Jo Daviess

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

9
health-based violations
237
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1999-06-01 → 1999-06-30
MCL Health-based Archived 1999-06-01 → 1999-06-30
MCL Health-based Archived 1999-02-01 → 1999-02-28
MCL Health-based Archived 1999-02-01 → 1999-02-28
MCL Health-based Archived 1998-04-01 → 1998-04-30
MCL Health-based Archived 1998-04-01 → 1998-04-30
MCL Health-based Archived 1997-09-01 → 1997-09-30
MCL Health-based Archived 1997-09-01 → 1997-09-30
MCL Health-based Archived 1997-09-01 → 1997-09-30
MR Monitoring Archived 1999-06-01 → 1999-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1188.5 µg/L 12%
of the EPA limit 10000 µg/L
worst single sample: 1190 µg/L
22/22 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
14/14 LCR 2024
Nitrate-Nitrite
1175 µg/L 12%
of the EPA limit 10000 µg/L
worst single sample: 1190 µg/L
11/11 SYR4 2012–2019
Copper
196 µg/L 15%
of the EPA limit 1300 µg/L
worst single sample: 201 µg/L
6/15 SYR4 2012–2018
Arsenic
1.0664 µg/L 11%
of the EPA limit 10 µg/L
worst single sample: 1.1 µg/L
3/3 SYR4 2012–2018
Barium
62.9 µg/L 3.1%
of the EPA limit 2000 µg/L
worst single sample: 63.4 µg/L
3/3 SYR4 2012–2018
Fluoride
1032.3 µg/L 26%
of the EPA limit 4000 µg/L
worst single sample: 1040 µg/L
3/3 SYR4 2012–2018
Selenium
4.934 µg/L 9.9%
of the EPA limit 50 µg/L
worst single sample: 5.02 µg/L
3/3 SYR4 2012–2018
Dibromochloromethane
1.485 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
2/3 SYR4 2013–2017
TTHM
2.625 µg/L 3.3%
of the EPA limit 80 µg/L
worst single sample: 2.7 µg/L
2/3 SYR4 2013–2017
Bromodichloromethane
1.2 µg/L
No EPA limit set
1/3 SYR4 2013–2017
Combined Radium (-226 And -228)
1.89 pCi/L 38%
of the EPA limit 5 pCi/L
1/1 SYR4 2017
66 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
EATON, DAVE
Phone
815-297-5751
Email
[email protected]

Frequently asked questions about Wienen Estates

Is Wienen Estates tap water safe to drink?

EPA monitoring detected 12 contaminants in Wienen Estates's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Wienen Estates's water?

EPA monitoring detected Nitrate, Lead, Nitrate-Nitrite, Copper, Arsenic, and others. The full list with the level and data source for each is above.

How many people does Wienen Estates serve?

Wienen Estates reports serving 95 people in Illinois, per its EPA record.

Has Wienen Estates had any water quality violations?

The EPA has 237 violations on file for Wienen Estates, of which 9 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.