← Illinois

Tap water quality report

Morris

EPA monitoring tested this supplier for 80 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
17
detected
14,775
people served
54
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Grundy

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

54
health-based violations
86
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1993-08-01 → 1993-08-31
MCL Health-based Archived 1993-08-01 → 1993-08-31
MCL Health-based Archived 1993-08-01 → 1993-08-31
MCL Health-based Archived 1993-08-01 → 1993-08-31
MCL Health-based Archived 1993-08-01 → 1993-08-31
MCL Health-based Archived 1993-08-01 → 1993-08-31
MCL Health-based Archived 1993-08-01 → 1993-08-31
MCL Health-based Archived 1993-08-01 → 1993-08-31
MCL Health-based Archived 1993-08-01 → 1993-08-31
MCL Health-based Archived 1993-08-01 → 1993-08-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
668.5 µg/L 51%
of the EPA limit 1300 µg/L
worst single sample: 958 µg/L
51/90 SYR4 2012–2018
Bromoform
21.8 µg/L
No EPA limit set
worst single sample: 25.4 µg/L
32/32 SYR4 2012–2019
Dibromochloromethane
14.635 µg/L
No EPA limit set
worst single sample: 15.4 µg/L
32/32 SYR4 2012–2019
TTHM
41.31 µg/L 52%
of the EPA limit 80 µg/L
worst single sample: 45.4 µg/L
32/32 SYR4 2012–2019
Bromodichloromethane
4.66 µg/L
No EPA limit set
worst single sample: 5.1 µg/L
29/32 SYR4 2012–2019
Dibromoacetic Acid
5.225 µg/L
No EPA limit set
worst single sample: 6.1 µg/L
26/32 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
5.225 µg/L 8.7%
of the EPA limit 60 µg/L
worst single sample: 6.1 µg/L
26/32 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
24/24 LCR 2025
Nitrate
649.7 µg/L 6.5%
of the EPA limit 10000 µg/L
worst single sample: 656 µg/L
22/22 SYR4 2012–2019
Combined Radium (-226 And -228)
4.65 pCi/L 93%
of the EPA limit 5 pCi/L
worst single sample: 4.9 pCi/L
11/11 SYR4 2012–2019
Nitrate-Nitrite
593 µg/L 5.9%
of the EPA limit 10000 µg/L
worst single sample: 656 µg/L
11/11 SYR4 2012–2019
Lead
18.175 µg/L 121%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 18.9 µg/L
6/90 SYR4 2012–2018
Trichloroacetic Acid
1.2 µg/L
No EPA limit set
4/32 SYR4 2012–2019
Barium
12.62 µg/L 0.6%
of the EPA limit 2000 µg/L
worst single sample: 12.8 µg/L
3/3 SYR4 2012–2018
Fluoride
948.4 µg/L 24%
of the EPA limit 4000 µg/L
worst single sample: 1000 µg/L
3/3 SYR4 2012–2018
Lithium
28.5 µg/L
No EPA limit set
2/2 UCMR-5 2024
Chloroform
1.4 µg/L
No EPA limit set
1/32 SYR4 2012–2019
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneDichloroacetic AcidEthylbenzeneHfpo-DaMercuryMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitritePfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GORDON, DALTON
Phone
815-942-2205
Email
[email protected]

Frequently asked questions about Morris

Is Morris tap water safe to drink?

EPA monitoring detected 17 contaminants in Morris's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Morris's water?

EPA monitoring detected Copper, Bromoform, Dibromochloromethane, TTHM, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Morris serve?

Morris reports serving 14,775 people in Illinois, per its EPA record.

Has Morris had any water quality violations?

The EPA has 86 violations on file for Morris, of which 54 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.