EPA monitoring tested this supplier for 78 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
20
detected
1,097
people served
164
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Greene

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

164
health-based violations
227
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-01-01 → 2021-03-31
MCL Health-based Resolved 2021-01-01 → 2021-03-31
MCL Health-based Resolved 2021-01-01 → 2021-03-31
MCL Health-based Resolved 2021-01-01 → 2021-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
71.345 µg/L
No EPA limit set
worst single sample: 87.4 µg/L
60/60 SYR4 2012–2019
TTHM
79.455 µg/L 99%
of the EPA limit 80 µg/L
worst single sample: 98 µg/L
60/60 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
88.4 µg/L 147%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 190 µg/L
59/60 SYR4 2012–2019
Trichloroacetic Acid
33.17 µg/L
No EPA limit set
worst single sample: 73.7 µg/L
59/60 SYR4 2012–2019
Dichloroacetic Acid
52.135 µg/L
No EPA limit set
worst single sample: 116 µg/L
58/60 SYR4 2012–2019
Bromodichloromethane
11.02 µg/L
No EPA limit set
worst single sample: 13.3 µg/L
57/60 SYR4 2012–2019
Dibromochloromethane
2.1 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
44/60 SYR4 2012–2019
Copper
710 µg/L 55%
of the EPA limit 1300 µg/L
worst single sample: 790 µg/L
30/30 SYR4 2012–2018
Atrazine
1.865 µg/L 62%
of the EPA limit 3 µg/L
worst single sample: 4.3 µg/L
24/33 SYR4 2012–2019
Lead
0.0027 mg/L 18%
of the EPA limit 0.0150 mg/L
23/23 LCR 2025
Nitrate
1800 µg/L 18%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
26.66 µg/L 178%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 48 µg/L
12/30 SYR4 2012–2018
Monochloroacetic Acid
6.628 µg/L
No EPA limit set
worst single sample: 6.97 µg/L
10/60 SYR4 2012–2019
Barium
56 µg/L 2.8%
of the EPA limit 2000 µg/L
8/8 SYR4 2012–2019
Fluoride
894.5 µg/L 22%
of the EPA limit 4000 µg/L
worst single sample: 898 µg/L
8/8 SYR4 2012–2019
Monobromoacetic Acid
12.75 µg/L
No EPA limit set
worst single sample: 13.4 µg/L
6/60 SYR4 2012–2019
Nitrate-Nitrite
1494 µg/L 15%
of the EPA limit 10000 µg/L
worst single sample: 1600 µg/L
3/3 SYR4 2012–2018
Simazine
4.06 µg/L 101%
of the EPA limit, at the 95th percentile of samples — 4 µg/L
worst single sample: 4.2 µg/L
3/22 SYR4 2012–2019
Arsenic
1.195 µg/L 12%
of the EPA limit 10 µg/L
worst single sample: 1.2 µg/L
2/8 SYR4 2012–2019
2,4-D
1.1 µg/L 1.6%
of the EPA limit 70 µg/L
1/10 SYR4 2012–2019
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TPAntimony, TotalBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HUNT, DEBBIE
Phone
217-368-2332
Email
[email protected]

Frequently asked questions about Greenfield

Is Greenfield tap water safe to drink?

EPA monitoring detected 20 contaminants in Greenfield's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Greenfield's water?

EPA monitoring detected Chloroform, TTHM, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Greenfield serve?

Greenfield reports serving 1,097 people in Illinois, per its EPA record.

Has Greenfield had any water quality violations?

The EPA has 227 violations on file for Greenfield, of which 164 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.