← Illinois

Tap water quality report

West Frankfort

EPA monitoring tested this supplier for 44 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
14
detected
8,650
people served
14
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Franklin

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

14
health-based violations
28
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2003-08-01 → 2003-08-31
MCL Health-based Archived 2003-08-01 → 2003-08-31
MCL Health-based Archived 2003-08-01 → 2003-08-31
MCL Health-based Archived 2000-11-01 → 2000-11-30
MCL Health-based Archived 2000-11-01 → 2000-11-30
MCL Health-based Archived 2000-11-01 → 2000-11-30
MCL Health-based Archived 2000-11-01 → 2000-11-30
MCL Health-based Archived 2000-10-01 → 2000-10-31
MCL Health-based Archived 2000-10-01 → 2000-10-31
MCL Health-based Archived 2000-06-01 → 2000-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
143.5 µg/L 11%
of the EPA limit 1300 µg/L
worst single sample: 1100 µg/L
54/60 SYR4 2014–2017
Bromodichloromethane
9.95875 µg/L
No EPA limit set
worst single sample: 10.61 µg/L
52/52 SYR4 2012–2019
Chloroform
41.795 µg/L
No EPA limit set
worst single sample: 47.76 µg/L
52/52 SYR4 2012–2019
Dibromochloromethane
4.0373 µg/L
No EPA limit set
worst single sample: 5.633 µg/L
52/52 SYR4 2012–2019
TTHM
53.662 µg/L 67%
of the EPA limit 80 µg/L
worst single sample: 60.46 µg/L
52/52 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
34.8 µg/L 58%
of the EPA limit 60 µg/L
worst single sample: 42.6 µg/L
49/52 SYR4 2012–2019
Trichloroacetic Acid
4.784 µg/L
No EPA limit set
worst single sample: 5.3 µg/L
45/52 SYR4 2012–2019
Dichloroacetic Acid
22.21 µg/L
No EPA limit set
worst single sample: 26.9 µg/L
44/52 SYR4 2012–2019
Lead
30 µg/L 200%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 90 µg/L
16/60 SYR4 2014–2017
Lead
0.0113 mg/L 75%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Dibromoacetic Acid
2.12 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
13/52 SYR4 2012–2019
Monobromoacetic Acid
12.62 µg/L
No EPA limit set
worst single sample: 12.8 µg/L
7/52 SYR4 2012–2019
Monochloroacetic Acid
3.6 µg/L
No EPA limit set
worst single sample: 3.78 µg/L
6/52 SYR4 2012–2019
Bromoform
1.8406 µg/L
No EPA limit set
worst single sample: 1.96 µg/L
3/52 SYR4 2012–2019
30 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
BOLEN, ANDREA
Phone
618-932-3262
Email
[email protected]

Frequently asked questions about West Frankfort

Is West Frankfort tap water safe to drink?

EPA monitoring detected 14 contaminants in West Frankfort's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in West Frankfort's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does West Frankfort serve?

West Frankfort reports serving 8,650 people in Illinois, per its EPA record.

Has West Frankfort had any water quality violations?

The EPA has 28 violations on file for West Frankfort, of which 14 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.