← Illinois

Tap water quality report

Hanover Park

EPA monitoring tested this supplier for 108 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
24
detected
37,470
people served
18
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Cook

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

18
health-based violations
104
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2009-07-01 → 2009-07-31
MCL Health-based Resolved 2009-07-01 → 2009-07-31
MCL Health-based Resolved 2009-07-01 → 2009-07-31
MCL Health-based Resolved 2009-07-01 → 2009-07-31
MCL Health-based Resolved 1998-07-01 → 1998-07-31
MCL Health-based Resolved 1998-07-01 → 1998-07-31
MCL Health-based Resolved 1998-07-01 → 1998-07-31
MCL Health-based Resolved 1984-09-14 → 1988-09-13
MCL Health-based Resolved 1984-09-14 → 1988-09-13
MCL Health-based Resolved 1984-09-14 → 1988-09-13

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
15.05 µg/L
No EPA limit set
worst single sample: 16.4 µg/L
71/71 SYR4 2012–2019
Chloroform
33.55 µg/L
No EPA limit set
worst single sample: 36.1 µg/L
71/71 SYR4 2012–2019
Dibromochloromethane
7.355 µg/L
No EPA limit set
worst single sample: 7.84 µg/L
71/71 SYR4 2012–2019
Dichloroacetic Acid
14.15 µg/L
No EPA limit set
worst single sample: 25.2 µg/L
71/71 SYR4 2012–2019
TTHM
56.2 µg/L 70%
of the EPA limit 80 µg/L
worst single sample: 59.7 µg/L
71/71 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
31.05 µg/L 52%
of the EPA limit 60 µg/L
worst single sample: 44 µg/L
71/71 SYR4 2012–2019
Trichloroacetic Acid
13.25 µg/L
No EPA limit set
worst single sample: 17 µg/L
71/71 SYR4 2012–2019
Monobromoacetic Acid
1.954 µg/L
No EPA limit set
worst single sample: 2.4 µg/L
57/71 SYR4 2012–2019
Nitrate
388 µg/L 3.9%
of the EPA limit 10000 µg/L
worst single sample: 396 µg/L
48/48 SYR4 2012–2019
Dibromoacetic Acid
2.017 µg/L
No EPA limit set
worst single sample: 2.06 µg/L
23/71 SYR4 2012–2019
Lead
0.0015 mg/L 9.7%
of the EPA limit 0.0150 mg/L
15/15 LCR 2023
Xylenes, Total
5.564 µg/L 0.1%
of the EPA limit 10000 µg/L
worst single sample: 10.8 µg/L
15/35 SYR4 2012–2019
Nitrate-Nitrite
338.4 µg/L 3.4%
of the EPA limit 10000 µg/L
worst single sample: 345 µg/L
12/12 SYR4 2012–2016
Barium
223.2 µg/L 11%
of the EPA limit 2000 µg/L
worst single sample: 233 µg/L
8/8 SYR4 2012–2018
Fluoride
1096.5 µg/L 27%
of the EPA limit 4000 µg/L
worst single sample: 1100 µg/L
8/8 SYR4 2012–2018
Copper
149.2 µg/L 11%
of the EPA limit 1300 µg/L
worst single sample: 151 µg/L
7/61 SYR4 2014–2017
Arsenic
0.7265 µg/L 7.3%
of the EPA limit 10 µg/L
worst single sample: 0.7310 µg/L
6/8 SYR4 2012–2018
Lead
7.096 µg/L 47%
of the EPA limit 15 µg/L
worst single sample: 7.57 µg/L
5/61 SYR4 2014–2017
Combined Radium (-226 And -228)
3.545 pCi/L 71%
of the EPA limit 5 pCi/L
worst single sample: 3.8 pCi/L
4/4 SYR4 2014–2017
Monochloroacetic Acid
3.906 µg/L
No EPA limit set
worst single sample: 3.93 µg/L
4/71 SYR4 2012–2019
Dalapon
1.3096 µg/L 0.7%
of the EPA limit 200 µg/L
worst single sample: 1.35 µg/L
2/26 SYR4 2012–2019
Ethylbenzene
2.015 µg/L 0.3%
of the EPA limit 700 µg/L
worst single sample: 2.09 µg/L
2/33 SYR4 2012–2019
Dichloromethane
1.12 µg/L 22%
of the EPA limit 5 µg/L
1/32 SYR4 2012–2019
Mercury
0.2880 µg/L 14%
of the EPA limit 2 µg/L
1/8 SYR4 2012–2018
84 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MALLER, JULIANA
Phone
630-823-5610
Email
[email protected]

Frequently asked questions about Hanover Park

Is Hanover Park tap water safe to drink?

EPA monitoring detected 24 contaminants in Hanover Park's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Hanover Park's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Hanover Park serve?

Hanover Park reports serving 37,470 people in Illinois, per its EPA record.

Has Hanover Park had any water quality violations?

The EPA has 104 violations on file for Hanover Park, of which 18 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.