← Illinois

Tap water quality report

Taylorville

EPA monitoring tested this supplier for 111 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

111
contaminants tested
21
detected
12,806
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Christian

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
73
violations on file
7
still open
ViolationTypeStatusPeriod
MR Monitoring Unaddressed 2026-01-01
MR Monitoring Unaddressed 2026-01-01
RPT Monitoring Unaddressed 2025-07-02
RPT Monitoring Unaddressed 2025-07-02
MR Monitoring Unaddressed 2025-07-01
MR Monitoring Unaddressed 2025-07-01
Other Monitoring Unaddressed 2025-07-01
MR Monitoring Resolved 2009-07-01 → 2009-09-30
MR Monitoring Resolved 2009-07-01 → 2009-09-30
MR Monitoring Resolved 2008-04-01 → 2008-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
10130 µg/L 101%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 13000 µg/L
388/398 SYR4 2012–2019
Dibromoacetic Acid
8.1 µg/L
No EPA limit set
worst single sample: 9.2 µg/L
108/108 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
29.295 µg/L 49%
of the EPA limit 60 µg/L
worst single sample: 38.6 µg/L
108/108 SYR4 2012–2019
Bromodichloromethane
22.326 µg/L
No EPA limit set
worst single sample: 25.81 µg/L
107/107 SYR4 2012–2019
Chloroform
32.21 µg/L
No EPA limit set
worst single sample: 57.9 µg/L
107/107 SYR4 2012–2019
TTHM
75.43 µg/L 94%
of the EPA limit 80 µg/L
worst single sample: 102.1 µg/L
107/107 SYR4 2012–2019
Dibromochloromethane
19.175 µg/L
No EPA limit set
worst single sample: 23.15 µg/L
106/107 SYR4 2012–2019
Bromoform
6.5 µg/L
No EPA limit set
worst single sample: 8.5 µg/L
105/107 SYR4 2012–2019
Dichloroacetic Acid
17.605 µg/L
No EPA limit set
worst single sample: 21.9 µg/L
98/108 SYR4 2012–2019
Trichloroacetic Acid
6.38 µg/L
No EPA limit set
worst single sample: 8.4 µg/L
79/108 SYR4 2012–2019
Nitrate-Nitrite
10800 µg/L 108%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 12700 µg/L
62/64 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
30/30 LCR 2026
Copper
128.8 µg/L 9.9%
of the EPA limit 1300 µg/L
worst single sample: 336 µg/L
17/120 SYR4 2014–2019
Barium
82.5 µg/L 4.1%
of the EPA limit 2000 µg/L
worst single sample: 89 µg/L
11/11 SYR4 2012–2019
Lead
53.6 µg/L 357%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 59 µg/L
10/120 SYR4 2014–2019
Fluoride
1004.05 µg/L 25%
of the EPA limit 4000 µg/L
worst single sample: 1010 µg/L
8/11 SYR4 2012–2019
Monobromoacetic Acid
6.5975 µg/L
No EPA limit set
worst single sample: 7.17 µg/L
6/108 SYR4 2012–2019
Combined Radium (-226 And -228)
2.224 pCi/L 44%
of the EPA limit 5 pCi/L
worst single sample: 2.26 pCi/L
4/4 SYR4 2012–2018
Selenium
2.975 µg/L 6%
of the EPA limit 50 µg/L
worst single sample: 3 µg/L
2/11 SYR4 2012–2019
Arsenic
1.1 µg/L 11%
of the EPA limit 10 µg/L
1/11 SYR4 2012–2019
Nitrite
269 µg/L 27%
of the EPA limit 1000 µg/L
1/64 SYR4 2012–2019
90 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromateChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloriteChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NICOL, JOSH
Phone
217-287-1441
Email
[email protected]

Frequently asked questions about Taylorville

Is Taylorville tap water safe to drink?

EPA monitoring detected 21 contaminants in Taylorville's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Taylorville's water?

EPA monitoring detected Nitrate, Dibromoacetic Acid, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Taylorville serve?

Taylorville reports serving 12,806 people in Illinois, per its EPA record.

Has Taylorville had any water quality violations?

The EPA has 73 violations on file for Taylorville, of which 0 are health-based (a contaminant limit or required treatment was breached) and 7 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.