← Illinois

Tap water quality report

Greenville

EPA monitoring tested this supplier for 109 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
19
detected
8,310
people served
30
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Bond

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

30
health-based violations
92
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2009-01-01 → 2009-03-31
TT Health-based Resolved 2009-01-01 → 2009-03-31
TT Health-based Resolved 2009-01-01 → 2009-03-31
TT Health-based Resolved 2009-01-01 → 2009-03-31
TT Health-based Resolved 2009-01-01 → 2009-03-31
TT Health-based Resolved 2009-01-01 → 2009-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chlorite
706 µg/L 71%
of the EPA limit 1000 µg/L
worst single sample: 780 µg/L
78/96 SYR4 2012–2019
Bromodichloromethane
11.42 µg/L
No EPA limit set
worst single sample: 11.7 µg/L
57/57 SYR4 2012–2019
Chloroform
61.9 µg/L
No EPA limit set
worst single sample: 76 µg/L
57/57 SYR4 2012–2019
Dichloroacetic Acid
24.4 µg/L
No EPA limit set
worst single sample: 35.8 µg/L
57/57 SYR4 2012–2019
TTHM
73.26 µg/L 92%
of the EPA limit 80 µg/L
worst single sample: 84 µg/L
57/57 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
48.76 µg/L 81%
of the EPA limit 60 µg/L
worst single sample: 66.9 µg/L
57/57 SYR4 2012–2019
Trichloroacetic Acid
25.32 µg/L
No EPA limit set
worst single sample: 39.5 µg/L
57/57 SYR4 2012–2019
Dibromochloromethane
1.92 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
29/57 SYR4 2012–2019
Lead
0.0140 mg/L 93%
of the EPA limit 0.0150 mg/L
25/25 LCR 2025
Nitrate
1090 µg/L 11%
of the EPA limit 10000 µg/L
12/16 SYR4 2012–2019
Barium
16.395 µg/L 0.8%
of the EPA limit 2000 µg/L
worst single sample: 16.5 µg/L
8/8 SYR4 2012–2019
Fluoride
1010 µg/L 25%
of the EPA limit 4000 µg/L
8/8 SYR4 2012–2019
Atrazine
2.4 µg/L 80%
of the EPA limit 3 µg/L
worst single sample: 2.8 µg/L
6/28 SYR4 2012–2019
Nitrate-Nitrite
1005 µg/L 10%
of the EPA limit 10000 µg/L
worst single sample: 1090 µg/L
6/8 SYR4 2012–2019
Arsenic
0.7647 µg/L 7.6%
of the EPA limit 10 µg/L
worst single sample: 0.7800 µg/L
4/8 SYR4 2012–2019
Monochloroacetic Acid
3.08 µg/L
No EPA limit set
worst single sample: 3.2 µg/L
4/57 SYR4 2012–2019
Copper
594.6 µg/L 46%
of the EPA limit 1300 µg/L
worst single sample: 623 µg/L
3/60 SYR4 2013–2019
Simazine
0.6010 µg/L 15%
of the EPA limit 4 µg/L
worst single sample: 0.6200 µg/L
3/28 SYR4 2012–2019
Lead
6.33 µg/L 42%
of the EPA limit 15 µg/L
1/60 SYR4 2013–2019
90 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LIGGETT, MICHELLE
Phone
618-664-1644
Email
[email protected]

Frequently asked questions about Greenville

Is Greenville tap water safe to drink?

EPA monitoring detected 19 contaminants in Greenville's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Greenville's water?

EPA monitoring detected Chlorite, Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Greenville serve?

Greenville reports serving 8,310 people in Illinois, per its EPA record.

Has Greenville had any water quality violations?

The EPA has 92 violations on file for Greenville, of which 30 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.