← Idaho

Tap water quality report

American Falls City of

EPA monitoring tested this supplier for 98 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

98
contaminants tested
15
detected
4,863
people served
12
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Power

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

12
health-based violations
214
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2014-11-01 → 2014-11-30
MCL Health-based Archived 2014-11-01 → 2014-11-30
MCL Health-based Archived 2013-12-01 → 2013-12-31
MCL Health-based Archived 2013-12-01 → 2013-12-31
MCL Health-based Archived 2013-08-01 → 2013-08-31
MCL Health-based Archived 2013-08-01 → 2013-08-31
MCL Health-based Archived 2013-01-01 → 2013-01-31
MCL Health-based Archived 2013-01-01 → 2013-01-31
MCL Health-based Archived 2009-11-01 → 2009-11-30
MCL Health-based Archived 2003-08-01 → 2003-08-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
7580 µg/L 76%
of the EPA limit 10000 µg/L
worst single sample: 8740 µg/L
100/122 SYR4 2012–2019
Arsenic
10 µg/L 100%
of the EPA limit 10 µg/L
27/27 SYR4 2013–2019
Combined Uranium
8.6285 µg/L 29%
of the EPA limit 30 µg/L
worst single sample: 8.79 µg/L
18/18 SYR4 2013–2019
Lead
0.0070 mg/L 47%
of the EPA limit 0.0150 mg/L
16/16 LCR 2025
Gross Alpha, Excl. Radon And U
16.305 pCi/L 109%
of the EPA limit, at the 95th percentile of samples — 15 pCi/L
worst single sample: 17.9 pCi/L
12/13 SYR4 2013–2019
Ethylene Dibromide
0.0295 µg/L 59%
of the EPA limit 0.0500 µg/L
worst single sample: 0.0320 µg/L
11/17 SYR4 2013–2019
Lithium
34 µg/L
No EPA limit set
10/12 UCMR-5 2024
Fluoride
500 µg/L 13%
of the EPA limit 4000 µg/L
6/6 SYR4 2013–2019
Combined Radium (-226 And -228)
1.2646 pCi/L 25%
of the EPA limit 5 pCi/L
worst single sample: 1.31 pCi/L
5/6 SYR4 2016
Nitrate-Nitrite
6870 µg/L 69%
of the EPA limit 10000 µg/L
worst single sample: 7580 µg/L
5/5 SYR4 2019
Barium
244.2 µg/L 12%
of the EPA limit 2000 µg/L
worst single sample: 258 µg/L
4/4 SYR4 2019
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
3/4 SYR4 2019
Selenium
8.4 µg/L 17%
of the EPA limit 50 µg/L
worst single sample: 9 µg/L
3/4 SYR4 2019
Di(2-ethylhexyl) Phthalate
0.8485 µg/L 14%
of the EPA limit 6 µg/L
worst single sample: 0.8600 µg/L
2/10 SYR4 2012–2019
Nitrite
245.5 µg/L 25%
of the EPA limit 1000 µg/L
worst single sample: 250 µg/L
2/5 SYR4 2019
83 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DALLING, SCOTT
Phone
208-541-0108
Email
[email protected]

Frequently asked questions about American Falls City of

Is American Falls City of tap water safe to drink?

EPA monitoring detected 15 contaminants in American Falls City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in American Falls City of's water?

EPA monitoring detected Nitrate, Arsenic, Combined Uranium, Lead, Gross Alpha, Excl. Radon And U, and others. The full list with the level and data source for each is above.

How many people does American Falls City of serve?

American Falls City of reports serving 4,863 people in Idaho, per its EPA record.

Has American Falls City of had any water quality violations?

The EPA has 214 violations on file for American Falls City of, of which 12 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.