← Idaho

Tap water quality report

Filer Water Works

EPA monitoring tested this supplier for 39 contaminants and detected 8. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

39
contaminants tested
8
detected
2,858
people served
183
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Twin Falls

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

183
health-based violations
261
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2021-04-01 → 2021-06-30
MCL Health-based Resolved 2021-04-01 → 2021-06-30
MCL Health-based Resolved 2021-04-01 → 2021-06-30
MCL Health-based Resolved 2021-01-01 → 2021-03-31
MCL Health-based Resolved 2021-01-01 → 2021-03-31
MCL Health-based Resolved 2021-01-01 → 2021-03-31
MCL Health-based Resolved 2021-01-01 → 2021-03-31
MCL Health-based Resolved 2021-01-01 → 2021-03-31
MCL Health-based Resolved 2020-10-01 → 2020-12-31
MCL Health-based Resolved 2020-10-01 → 2020-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Arsenic
12.59 µg/L 126%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
worst single sample: 13 µg/L
43/44 SYR4 2012–2019
Nitrate
3942.5 µg/L 39%
of the EPA limit 10000 µg/L
worst single sample: 4040 µg/L
36/42 SYR4 2012–2019
Lead
0.0028 mg/L 19%
of the EPA limit 0.0150 mg/L
19/19 LCR 2026
TTHM
44.0185 µg/L 55%
of the EPA limit 80 µg/L
worst single sample: 52 µg/L
18/18 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
13.375 µg/L 22%
of the EPA limit 60 µg/L
worst single sample: 22.3 µg/L
18/18 SYR4 2012–2019
Fluoride
880 µg/L 22%
of the EPA limit 4000 µg/L
2/2 SYR4 2016–2017
Combined Uranium
9.51 µg/L 32%
of the EPA limit 30 µg/L
1/1 SYR4 2016
Gross Alpha, Excl. Radon And U
3.7 pCi/L 25%
of the EPA limit 15 pCi/L
1/2 SYR4 2016–2017
31 contaminants tested, none detected
1,2-DIBROMO-3-CHLOROPROPANE2,4,5-TP2,4-DAsbestosAtrazineBhc-GammaBenzo(A)PyreneCarbofuranChlordaneCombined Radium (-226 And -228)DalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorOxamylPentachlorophenolPicloramSimazineTotal Polychlorinated Biphenyls (PCB)Toxaphene

Utility contact

Contact
VEENSTRA, JAMES
Phone
208-326-5001
Email
[email protected]

Frequently asked questions about Filer Water Works

Is Filer Water Works tap water safe to drink?

EPA monitoring detected 8 contaminants in Filer Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Filer Water Works's water?

EPA monitoring detected Arsenic, Nitrate, Lead, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Filer Water Works serve?

Filer Water Works reports serving 2,858 people in Idaho, per its EPA record.

Has Filer Water Works had any water quality violations?

The EPA has 261 violations on file for Filer Water Works, of which 183 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.