← Iowa

Tap water quality report

Sheldon Water Department

EPA monitoring tested this supplier for 89 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

89
contaminants tested
20
detected
5,512
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
O'Brien

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
13
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2006-08-01 → 2006-08-31
MR Monitoring Resolved 2006-08-01 → 2006-08-31
MR Monitoring Resolved 2006-08-01 → 2006-08-31
MR Monitoring Resolved 2006-08-01 → 2006-08-31
MR Monitoring Resolved 2000-03-01 → 2000-03-31
MR Monitoring Resolved 2000-03-01 → 2000-03-31
MR Monitoring Resolved 2000-03-01 → 2000-03-31
MR Monitoring Resolved 2000-03-01 → 2000-03-31
MR Monitoring Resolved 1997-11-01 → 1997-11-30
MR Monitoring Resolved 1997-11-01 → 1997-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
1005 µg/L 77%
of the EPA limit 1300 µg/L
worst single sample: 1400 µg/L
60/60 SYR4 2012–2018
Bromodichloromethane
31.2 µg/L
No EPA limit set
worst single sample: 32.7 µg/L
56/56 SYR4 2012–2019
Chloroform
30.1 µg/L
No EPA limit set
worst single sample: 34.8 µg/L
56/56 SYR4 2012–2019
Dibromochloromethane
29.925 µg/L
No EPA limit set
worst single sample: 34.1 µg/L
56/56 SYR4 2012–2019
TTHM
94.325 µg/L 118%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 102 µg/L
56/56 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
53.225 µg/L 89%
of the EPA limit 60 µg/L
worst single sample: 68 µg/L
56/56 SYR4 2012–2019
Trichloroacetic Acid
6.93 µg/L
No EPA limit set
worst single sample: 8.49 µg/L
56/56 SYR4 2012–2019
Dibromoacetic Acid
7.9135 µg/L
No EPA limit set
worst single sample: 8.54 µg/L
54/56 SYR4 2012–2019
Dichloroacetic Acid
10.805 µg/L
No EPA limit set
worst single sample: 13.8 µg/L
54/56 SYR4 2012–2019
Bromoform
9.622 µg/L
No EPA limit set
worst single sample: 12.6 µg/L
53/56 SYR4 2012–2019
Monochloroacetic Acid
43.59 µg/L
No EPA limit set
worst single sample: 53.3 µg/L
43/56 SYR4 2012–2019
Lead
6.07 µg/L 40%
of the EPA limit 15 µg/L
worst single sample: 15.1 µg/L
39/60 SYR4 2012–2018
Monobromoacetic Acid
5.406 µg/L
No EPA limit set
worst single sample: 5.73 µg/L
19/56 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
16/16 LCR 2024
Nitrate
1990 µg/L 20%
of the EPA limit 10000 µg/L
12/18 SYR4 2012–2019
Combined Radium (-226 And -228)
3.785 pCi/L 76%
of the EPA limit 5 pCi/L
worst single sample: 3.9 pCi/L
2/3 SYR4 2012–2018
Barium
68.6 µg/L 3.4%
of the EPA limit 2000 µg/L
1/1 SYR4 2015
Fluoride
700 µg/L 18%
of the EPA limit 4000 µg/L
1/1 SYR4 2015
Selenium
1.8 µg/L 3.6%
of the EPA limit 50 µg/L
1/1 SYR4 2015
Lithium
44 µg/L
No EPA limit set
1/1 UCMR-5 2025
69 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBenzeneBenzo(A)PyreneChlorobenzeneCadmiumCarbon TetrachlorideChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylbenzeneHfpo-DaLassoMercuryNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SHELDON WATER DEPARTMENT
Phone
712-324-2845
Email
[email protected]

Frequently asked questions about Sheldon Water Department

Is Sheldon Water Department tap water safe to drink?

EPA monitoring detected 20 contaminants in Sheldon Water Department's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sheldon Water Department's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Sheldon Water Department serve?

Sheldon Water Department reports serving 5,512 people in Iowa, per its EPA record.

Has Sheldon Water Department had any water quality violations?

The EPA has 13 violations on file for Sheldon Water Department, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.