← Iowa

Tap water quality report

Ft Madison Muni Water Works

EPA monitoring tested this supplier for 80 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
14
detected
11,087
people served
22
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Lee

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

22
health-based violations
216
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1998-08-01 → 1998-08-31
MCL Health-based Resolved 1998-08-01 → 1998-08-31
MCL Health-based Resolved 1998-08-01 → 1998-08-31
MCL Health-based Resolved 1998-08-01 → 1998-08-31
MCL Health-based Resolved 1998-07-01 → 1998-07-31
MCL Health-based Resolved 1998-07-01 → 1998-07-31
MCL Health-based Resolved 1998-07-01 → 1998-07-31
MCL Health-based Resolved 1997-12-01 → 1997-12-31
MCL Health-based Resolved 1997-12-01 → 1997-12-31
MCL Health-based Resolved 1997-12-01 → 1997-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
3.9 µg/L
No EPA limit set
worst single sample: 4.8 µg/L
92/92 SYR4 2012–2019
Chloroform
6.98 µg/L
No EPA limit set
worst single sample: 16 µg/L
92/92 SYR4 2012–2019
Dibromochloromethane
2.9 µg/L
No EPA limit set
worst single sample: 10 µg/L
90/92 SYR4 2012–2019
TTHM
14.1 µg/L 18%
of the EPA limit 80 µg/L
worst single sample: 24 µg/L
90/92 SYR4 2012–2019
Copper
83.5 µg/L 6.4%
of the EPA limit 1300 µg/L
worst single sample: 150 µg/L
74/91 SYR4 2012–2018
Dichloroacetic Acid
4 µg/L
No EPA limit set
19/92 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
17/17 LCR 2024
Bromoform
1.1 µg/L
No EPA limit set
16/92 SYR4 2012–2019
Lead
307.95 µg/L 2053%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 470 µg/L
8/91 SYR4 2012–2018
Nitrate
1000 µg/L 10%
of the EPA limit 10000 µg/L
6/16 SYR4 2012–2019
Dibromoacetic Acid
1 µg/L
No EPA limit set
1/92 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
6 µg/L 10%
of the EPA limit 60 µg/L
1/92 SYR4 2012–2019
Trichloroacetic Acid
2 µg/L
No EPA limit set
1/92 SYR4 2012–2019
Xylenes, Total
2.3 µg/L 0%
of the EPA limit 10000 µg/L
1/2 SYR4 2015–2019
66 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAsbestosAtrazineBenzeneBenzo(A)PyreneChlorobenzeneCarbon TetrachlorideCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylbenzeneHfpo-DaLassoMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FT MADISON MUNI WATER WORKS
Phone
319-372-7700
Email
[email protected]

Frequently asked questions about Ft Madison Muni Water Works

Is Ft Madison Muni Water Works tap water safe to drink?

EPA monitoring detected 14 contaminants in Ft Madison Muni Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ft Madison Muni Water Works's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Copper, and others. The full list with the level and data source for each is above.

How many people does Ft Madison Muni Water Works serve?

Ft Madison Muni Water Works reports serving 11,087 people in Iowa, per its EPA record.

Has Ft Madison Muni Water Works had any water quality violations?

The EPA has 216 violations on file for Ft Madison Muni Water Works, of which 22 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.