← Iowa

Tap water quality report

Lake Macbride Heights Hoa

EPA monitoring tested this supplier for 47 contaminants and detected 5. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

47
contaminants tested
5
detected
69
people served
28
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Johnson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

28
health-based violations
67
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2006-08-01 → 2006-08-31
MCL Health-based Resolved 2006-08-01 → 2006-08-31
MCL Health-based Resolved 2006-08-01 → 2006-08-31
MCL Health-based Resolved 2006-08-01 → 2006-08-31
MCL Health-based Resolved 2006-07-01 → 2006-07-31
MCL Health-based Resolved 2006-07-01 → 2006-07-31
MCL Health-based Resolved 2006-07-01 → 2006-07-31
MCL Health-based Resolved 2002-06-01 → 2002-06-30
MCL Health-based Resolved 2002-06-01 → 2002-06-30
MCL Health-based Resolved 2002-06-01 → 2002-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
12/12 LCR 2023
Combined Radium (-226 And -228)
3.385 pCi/L 68%
of the EPA limit 5 pCi/L
worst single sample: 3.4 pCi/L
2/2 SYR4 2016–2019
Barium
390 µg/L 20%
of the EPA limit 2000 µg/L
1/1 SYR4 2015
Copper
10 µg/L 0.8%
of the EPA limit 1300 µg/L
1/10 SYR4 2014–2017
Fluoride
220 µg/L 5.5%
of the EPA limit 4000 µg/L
1/1 SYR4 2015
42 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBenzeneBenzo(A)PyreneChlorobenzeneCadmiumCarbon TetrachlorideChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylbenzeneLassoLeadMercuryNitratePentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LAKE MACBRIDE HTS HOA
Phone
319-936-4189
Email
[email protected]

Frequently asked questions about Lake Macbride Heights Hoa

Is Lake Macbride Heights Hoa tap water safe to drink?

EPA monitoring detected 5 contaminants in Lake Macbride Heights Hoa's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lake Macbride Heights Hoa's water?

EPA monitoring detected Lead, Combined Radium (-226 And -228), Barium, Copper, Fluoride. The full list with the level and data source for each is above.

How many people does Lake Macbride Heights Hoa serve?

Lake Macbride Heights Hoa reports serving 69 people in Iowa, per its EPA record.

Has Lake Macbride Heights Hoa had any water quality violations?

The EPA has 67 violations on file for Lake Macbride Heights Hoa, of which 28 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.