Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 1992-07-01 → 1992-07-31 |
| MCL | Health-based | Resolved | 1992-07-01 → 1992-07-31 |
| MCL | Health-based | Resolved | 1992-07-01 → 1992-07-31 |
| MCL | Health-based | Resolved | 1992-07-01 → 1992-07-31 |
| MR | Monitoring | Resolved | 2005-07-01 → 2007-08-31 |
| MR | Monitoring | Resolved | 2005-07-01 → 2007-08-31 |
| MR | Monitoring | Resolved | 2005-07-01 → 2007-08-31 |
| MR | Monitoring | Resolved | 2005-07-01 → 2007-08-31 |
| MR | Monitoring | Resolved | 2005-07-01 → 2007-08-31 |
| MR | Monitoring | Resolved | 2002-07-01 → 2002-08-02 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Lead | 0.0046 mg/L 31% of the EPA limit 0.0150 mg/L | 13/13 | LCR | 2023 |
| Copper | 437.85 µg/L 34% of the EPA limit 1300 µg/L
worst single sample: 450 µg/L | 10/10 | SYR4 | 2014–2017 |
| Lead | 5.74 µg/L 38% of the EPA limit 15 µg/L
worst single sample: 6.5 µg/L | 9/10 | SYR4 | 2014–2017 |
| Bromodichloromethane | 2.693 µg/L No EPA limit set
worst single sample: 2.78 µg/L | 3/3 | SYR4 | 2014–2018 |
| Chloroform | 5.687 µg/L No EPA limit set
worst single sample: 6.04 µg/L | 3/3 | SYR4 | 2014–2018 |
| Dibromochloromethane | 1.272 µg/L No EPA limit set
worst single sample: 1.29 µg/L | 3/3 | SYR4 | 2014–2018 |
| TTHM | 9.382 µg/L 12% of the EPA limit 80 µg/L
worst single sample: 9.79 µg/L | 3/3 | SYR4 | 2014–2018 |
| Trichloroacetic Acid | 2.342 µg/L No EPA limit set
worst single sample: 2.51 µg/L | 3/3 | SYR4 | 2014–2018 |
| Combined Radium (-226 And -228) | 1.585 pCi/L 32% of the EPA limit 5 pCi/L
worst single sample: 1.6 pCi/L | 2/2 | SYR4 | 2013–2019 |
| Barium | 96 µg/L 4.8% of the EPA limit 2000 µg/L | 1/1 | SYR4 | 2012 |
| Dibromoacetic Acid | 0.6400 µg/L No EPA limit set | 1/3 | SYR4 | 2014–2018 |
| Dichloroacetic Acid | 3.09 µg/L No EPA limit set | 1/3 | SYR4 | 2014–2018 |
| Fluoride | 300 µg/L 7.5% of the EPA limit 4000 µg/L | 1/1 | SYR4 | 2012 |
| Monobromoacetic Acid | 1.85 µg/L No EPA limit set | 1/3 | SYR4 | 2014–2018 |
| Total Haloacetic Acids (HAA5) | 8.09 µg/L 13% of the EPA limit 60 µg/L | 1/3 | SYR4 | 2014–2018 |
45 contaminants tested, none detected
Utility contact
Frequently asked questions about Thunder Hills Home & Utility Assoc.
Is Thunder Hills Home & Utility Assoc. tap water safe to drink?
EPA monitoring detected 15 contaminants in Thunder Hills Home & Utility Assoc.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Thunder Hills Home & Utility Assoc.'s water?
EPA monitoring detected Lead, Copper, Lead, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Thunder Hills Home & Utility Assoc. serve?
Thunder Hills Home & Utility Assoc. reports serving 300 people in Iowa, per its EPA record.
Has Thunder Hills Home & Utility Assoc. had any water quality violations?
The EPA has 99 violations on file for Thunder Hills Home & Utility Assoc., of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.