← Iowa

Tap water quality report

Lost Canyon Mhp (Peosta)

EPA monitoring tested this supplier for 60 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

60
contaminants tested
12
detected
97
people served
10
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Dubuque

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

10
health-based violations
47
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2003-01-01 → 2003-01-31
MCL Health-based Resolved 2003-01-01 → 2003-01-31
MCL Health-based Resolved 2003-01-01 → 2003-01-31
MCL Health-based Resolved 2003-01-01 → 2003-01-31
MCL Health-based Resolved 2003-01-01 → 2003-01-31
MCL Health-based Resolved 2003-01-01 → 2003-01-31
MCL Health-based Resolved 2003-01-01 → 2003-01-31
MCL Health-based Resolved 2003-01-01 → 2003-01-31
MCL Health-based Resolved 2003-01-01 → 2003-01-31
MCL Health-based Resolved 2003-01-01 → 2003-01-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0124 mg/L 83%
of the EPA limit 0.0150 mg/L
13/13 LCR 2023
Copper
19.675 µg/L 1.5%
of the EPA limit 1300 µg/L
worst single sample: 23.5 µg/L
10/10 SYR4 2014–2017
Nitrate
300 µg/L 3%
of the EPA limit 10000 µg/L
4/16 SYR4 2012–2019
Bromodichloromethane
1.0305 µg/L
No EPA limit set
worst single sample: 1.04 µg/L
2/2 SYR4 2014–2017
Chloroform
2.03 µg/L
No EPA limit set
worst single sample: 2.05 µg/L
2/2 SYR4 2014–2017
Combined Radium (-226 And -228)
1.89 pCi/L 38%
of the EPA limit 5 pCi/L
worst single sample: 1.9 pCi/L
2/2 SYR4 2013–2019
Lead
3.945 µg/L 26%
of the EPA limit 15 µg/L
worst single sample: 4.1 µg/L
2/10 SYR4 2014–2017
TTHM
3.564 µg/L 4.5%
of the EPA limit 80 µg/L
worst single sample: 3.62 µg/L
2/2 SYR4 2014–2017
Trichloroacetic Acid
0.8950 µg/L
No EPA limit set
worst single sample: 0.9000 µg/L
2/2 SYR4 2014–2017
Barium
182 µg/L 9.1%
of the EPA limit 2000 µg/L
1/1 SYR4 2013
Dibromochloromethane
0.5300 µg/L
No EPA limit set
1/2 SYR4 2014–2017
Fluoride
200 µg/L 5%
of the EPA limit 4000 µg/L
1/1 SYR4 2013
48 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBenzeneBenzo(A)PyreneBromoformChlorobenzeneCadmiumCarbon TetrachlorideChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylbenzeneGlyphosateLassoMercuryMonobromoacetic AcidMonochloroacetic AcidPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)TrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LOST CANYON MHP (PEOSTA)
Phone
563-599-9538
Email
[email protected]

Frequently asked questions about Lost Canyon Mhp (Peosta)

Is Lost Canyon Mhp (Peosta) tap water safe to drink?

EPA monitoring detected 12 contaminants in Lost Canyon Mhp (Peosta)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lost Canyon Mhp (Peosta)'s water?

EPA monitoring detected Lead, Copper, Nitrate, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Lost Canyon Mhp (Peosta) serve?

Lost Canyon Mhp (Peosta) reports serving 97 people in Iowa, per its EPA record.

Has Lost Canyon Mhp (Peosta) had any water quality violations?

The EPA has 47 violations on file for Lost Canyon Mhp (Peosta), of which 10 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.