Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2000-10-01 → 2001-09-30 |
| MR | Monitoring | Resolved | 2000-10-01 → 2001-09-30 |
| MR | Monitoring | Resolved | 2000-10-01 → 2001-09-30 |
| MR | Monitoring | Resolved | 2000-10-01 → 2001-09-30 |
| MR | Monitoring | Resolved | 2000-10-01 → 2001-09-30 |
| MR | Monitoring | Resolved | 2000-10-01 → 2001-09-30 |
| MR | Monitoring | Resolved | 2000-10-01 → 2001-09-30 |
| MR | Monitoring | Resolved | 2000-10-01 → 2001-09-30 |
| MR | Monitoring | Resolved | 1992-07-01 → 2002-03-01 |
| MR | Monitoring | Resolved | 1990-10-01 → 1990-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 46.62 µg/L 3.6% of the EPA limit 1300 µg/L
worst single sample: 91.1 µg/L | 59/60 | SYR4 | 2013–2019 |
| Lead | 5.2 µg/L 35% of the EPA limit 15 µg/L
worst single sample: 11.4 µg/L | 26/60 | SYR4 | 2013–2019 |
| Bromodichloromethane | 10.975 µg/L No EPA limit set
worst single sample: 11.8 µg/L | 16/16 | SYR4 | 2013–2019 |
| Bromoform | 4.9175 µg/L No EPA limit set
worst single sample: 5.57 µg/L | 16/16 | SYR4 | 2013–2019 |
| Chloroform | 34.4 µg/L No EPA limit set
worst single sample: 38.9 µg/L | 16/16 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 4.805 µg/L No EPA limit set
worst single sample: 5.03 µg/L | 16/16 | SYR4 | 2013–2019 |
| Dibromochloromethane | 12.2 µg/L No EPA limit set | 16/16 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 7.46 µg/L No EPA limit set
worst single sample: 10.1 µg/L | 16/16 | SYR4 | 2013–2019 |
| TTHM | 53.825 µg/L 67% of the EPA limit 80 µg/L
worst single sample: 60.5 µg/L | 16/16 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 23.125 µg/L 39% of the EPA limit 60 µg/L
worst single sample: 29.2 µg/L | 16/16 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 1.6675 µg/L No EPA limit set
worst single sample: 1.99 µg/L | 16/16 | SYR4 | 2013–2019 |
| Monochloroacetic Acid | 14.97 µg/L No EPA limit set
worst single sample: 20.5 µg/L | 15/16 | SYR4 | 2013–2019 |
| Lead | 0.0012 mg/L 8% of the EPA limit 0.0150 mg/L | 13/13 | LCR | 2025 |
| Nitrate | 1300 µg/L 13% of the EPA limit 10000 µg/L | 6/16 | SYR4 | 2012–2019 |
| Lithium | 14 µg/L No EPA limit set | 2/2 | UCMR-5 | 2025 |
| Barium | 27.2 µg/L 1.4% of the EPA limit 2000 µg/L | 1/1 | SYR4 | 2013 |
| Fluoride | 800 µg/L 20% of the EPA limit 4000 µg/L | 1/1 | SYR4 | 2013 |
73 contaminants tested, none detected
Utility contact
Frequently asked questions about Denison Water Supply
Is Denison Water Supply tap water safe to drink?
EPA monitoring detected 17 contaminants in Denison Water Supply's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Denison Water Supply's water?
EPA monitoring detected Copper, Lead, Bromodichloromethane, Bromoform, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Denison Water Supply serve?
Denison Water Supply reports serving 9,381 people in Iowa, per its EPA record.
Has Denison Water Supply had any water quality violations?
The EPA has 13 violations on file for Denison Water Supply, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.