← Iowa

Tap water quality report

Ia Regional Utilities Assoc (Waverly)

EPA monitoring tested this supplier for 90 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

90
contaminants tested
19
detected
37,820
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Black Hawk, Bremer, Butler, Grundy, Hardin, Jasper, Marshall, Story

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
8
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2014-11-01 → 2014-11-30
MR Monitoring Resolved 2014-11-01 → 2014-11-30
MR Monitoring Resolved 2014-11-01 → 2014-11-30
MR Monitoring Resolved 2014-11-01 → 2014-11-30
MR Monitoring Resolved 2014-11-01 → 2014-11-30
MR Monitoring Resolved 2014-11-01 → 2014-11-30
MR Monitoring Resolved 2014-11-01 → 2014-11-30
MR Monitoring Resolved 2014-11-01 → 2014-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
150 µg/L 12%
of the EPA limit 1300 µg/L
worst single sample: 1270 µg/L
129/136 SYR4 2012–2019
Nitrate
4900 µg/L 49%
of the EPA limit 10000 µg/L
worst single sample: 5200 µg/L
124/124 SYR4 2012–2019
Dibromoacetic Acid
4.582 µg/L
No EPA limit set
worst single sample: 5.62 µg/L
77/127 SYR4 2012–2019
Trichloroacetic Acid
3.515 µg/L
No EPA limit set
worst single sample: 4.2 µg/L
68/127 SYR4 2012–2019
Dichloroacetic Acid
12.25 µg/L
No EPA limit set
worst single sample: 15.1 µg/L
67/127 SYR4 2012–2019
Bromodichloromethane
20.43 µg/L
No EPA limit set
worst single sample: 23.2 µg/L
64/127 SYR4 2012–2019
Chloroform
52.1 µg/L
No EPA limit set
worst single sample: 70.4 µg/L
64/127 SYR4 2012–2019
Dibromochloromethane
16.28 µg/L
No EPA limit set
worst single sample: 22.5 µg/L
64/127 SYR4 2012–2019
TTHM
79.06 µg/L 99%
of the EPA limit 80 µg/L
worst single sample: 95.5 µg/L
64/127 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
22.77 µg/L 38%
of the EPA limit 60 µg/L
worst single sample: 30.6 µg/L
63/127 SYR4 2012–2019
Bromoform
5.673 µg/L
No EPA limit set
worst single sample: 6.77 µg/L
55/127 SYR4 2012–2019
Monochloroacetic Acid
12.37 µg/L
No EPA limit set
worst single sample: 16.8 µg/L
39/127 SYR4 2012–2019
Lead
111 µg/L 740%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 159 µg/L
36/136 SYR4 2012–2019
Monobromoacetic Acid
8.435 µg/L
No EPA limit set
worst single sample: 8.58 µg/L
11/127 SYR4 2012–2019
Lead
0.0015 mg/L 10%
of the EPA limit 0.0150 mg/L
9/9 LCR 2025
Lithium
140 µg/L
No EPA limit set
4/6 UCMR-5 2025
Barium
42.99 µg/L 2.1%
of the EPA limit 2000 µg/L
worst single sample: 43.2 µg/L
2/2 SYR4 2014–2015
Fluoride
690 µg/L 17%
of the EPA limit 4000 µg/L
worst single sample: 700 µg/L
2/2 SYR4 2014–2015
Selenium
1 µg/L 2%
of the EPA limit 50 µg/L
2/2 SYR4 2014–2015
71 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBenzeneBenzo(A)PyreneChlorobenzeneCadmiumCarbon TetrachlorideChromiumCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylbenzeneGlyphosateHfpo-DaLassoMercuryNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
IOWA REGIONAL UTILITIES ASSOCIATION
Phone
641-792-7011
Email
[email protected]

Frequently asked questions about Ia Regional Utilities Assoc (Waverly)

Is Ia Regional Utilities Assoc (Waverly) tap water safe to drink?

EPA monitoring detected 19 contaminants in Ia Regional Utilities Assoc (Waverly)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ia Regional Utilities Assoc (Waverly)'s water?

EPA monitoring detected Copper, Nitrate, Dibromoacetic Acid, Trichloroacetic Acid, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Ia Regional Utilities Assoc (Waverly) serve?

Ia Regional Utilities Assoc (Waverly) reports serving 37,820 people in Iowa, per its EPA record.

Has Ia Regional Utilities Assoc (Waverly) had any water quality violations?

The EPA has 8 violations on file for Ia Regional Utilities Assoc (Waverly), of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.