← Hawaii

Tap water quality report

Pacific Missile Range Facility

EPA monitoring tested this supplier for 81 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

81
contaminants tested
13
detected
1,200
people served
3
health-based violations
Water source
Ground water
Ownership
Federal government
Counties served
Kauai

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
3
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2006-11-01 → 2006-11-30
MCL Health-based Archived 2006-11-01 → 2006-11-30
MCL Health-based Archived 2006-11-01 → 2006-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
164.5 µg/L 13%
of the EPA limit 1300 µg/L
worst single sample: 316 µg/L
31/43 SYR4 2013–2019
Nitrate
1100 µg/L 11%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Bromoform
6.78 µg/L
No EPA limit set
worst single sample: 7.9 µg/L
8/8 SYR4 2012–2019
Nitrate-Nitrite
1100 µg/L 11%
of the EPA limit 10000 µg/L
8/8 SYR4 2012–2019
TTHM
7.43 µg/L 9.3%
of the EPA limit 80 µg/L
worst single sample: 8.9 µg/L
8/8 SYR4 2012–2019
Lead
668.9 µg/L 4459%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 782 µg/L
7/43 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
4/4 LCR 2022
Chromium
5.6855 µg/L 5.7%
of the EPA limit 100 µg/L
worst single sample: 5.69 µg/L
2/3 SYR4 2013–2017
Fluoride
209.5 µg/L 5.2%
of the EPA limit 4000 µg/L
worst single sample: 210 µg/L
2/10 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
3.39 µg/L 5.7%
of the EPA limit 60 µg/L
worst single sample: 3.5 µg/L
2/8 SYR4 2012–2019
Dibromoacetic Acid
1.3 µg/L
No EPA limit set
1/8 SYR4 2012–2019
Dibromochloromethane
1 µg/L
No EPA limit set
1/7 SYR4 2012–2019
Monobromoacetic Acid
3.5 µg/L
No EPA limit set
1/8 SYR4 2012–2019
68 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneMercuryMethoxychlorMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ENG, SHERRI
Phone
808-471-3858
Email
[email protected]

Frequently asked questions about Pacific Missile Range Facility

Is Pacific Missile Range Facility tap water safe to drink?

EPA monitoring detected 13 contaminants in Pacific Missile Range Facility's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pacific Missile Range Facility's water?

EPA monitoring detected Copper, Nitrate, Bromoform, Nitrate-Nitrite, TTHM, and others. The full list with the level and data source for each is above.

How many people does Pacific Missile Range Facility serve?

Pacific Missile Range Facility reports serving 1,200 people in Hawaii, per its EPA record.

Has Pacific Missile Range Facility had any water quality violations?

The EPA has 3 violations on file for Pacific Missile Range Facility, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.