Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Archived | 2019-01-01 → 2019-12-31 |
| MR | Monitoring | Archived | 2019-01-01 → 2019-12-31 |
| MR | Monitoring | Archived | 2018-01-01 → 2018-12-31 |
| MR | Monitoring | Archived | 2018-01-01 → 2018-12-31 |
| MR | Monitoring | Resolved | 2017-01-01 → 2017-12-31 |
| MR | Monitoring | Resolved | 2017-01-01 → 2017-12-31 |
| MON | Monitoring | Resolved | 2016-09-01 → 2016-09-30 |
| MR | Monitoring | Resolved | 2016-09-01 → 2016-09-30 |
| MR | Monitoring | Archived | 2014-07-01 → 2014-09-30 |
| MR | Monitoring | Resolved | 2012-01-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 65.77 µg/L 82% of the EPA limit 80 µg/L
worst single sample: 86.7 µg/L | 15/15 | SYR4 | 2014–2019 |
| Total Haloacetic Acids (HAA5) | 16.99 µg/L 28% of the EPA limit 60 µg/L
worst single sample: 20.7 µg/L | 15/15 | SYR4 | 2014–2019 |
| Lead | 0.00040 mg/L 2.7% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2024 |
| Nitrate | 10900 µg/L 109% of the EPA limit, at the 95th percentile of samples — 10000 µg/L | 10/20 | SYR4 | 2012–2019 |
| Fluoride | 1200 µg/L 30% of the EPA limit 4000 µg/L | 6/6 | SYR4 | 2012–2018 |
| Barium | 5.33 µg/L 0.3% of the EPA limit 2000 µg/L
worst single sample: 5.4 µg/L | 3/3 | SYR4 | 2012–2018 |
| Copper | 16.7 µg/L 1.3% of the EPA limit 1300 µg/L
worst single sample: 17 µg/L | 3/3 | SYR4 | 2012–2018 |
| Chromium | 1.97 µg/L 2% of the EPA limit 100 µg/L
worst single sample: 2 µg/L | 3/3 | SYR4 | 2012–2018 |
| Selenium | 2.45 µg/L 4.9% of the EPA limit 50 µg/L
worst single sample: 2.5 µg/L | 3/3 | SYR4 | 2012–2018 |
| Nitrite | 19.15 µg/L 1.9% of the EPA limit 1000 µg/L
worst single sample: 20 µg/L | 2/10 | SYR4 | 2012–2019 |
| Xylenes, Total | 0.7870 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 0.8000 µg/L | 2/11 | SYR4 | 2012–2019 |
| Arsenic | 1.6 µg/L 16% of the EPA limit 10 µg/L | 1/3 | SYR4 | 2012–2018 |
| Cadmium | 1 µg/L 20% of the EPA limit 5 µg/L | 1/3 | SYR4 | 2012–2018 |
| Dalapon | 0.3400 µg/L 0.2% of the EPA limit 200 µg/L | 1/3 | SYR4 | 2012–2018 |
| Ethylbenzene | 0.1000 µg/L 0% of the EPA limit 700 µg/L | 1/6 | SYR4 | 2012–2018 |
83 contaminants tested, none detected
Utility contact
Frequently asked questions about Kings Gate Club
Is Kings Gate Club tap water safe to drink?
EPA monitoring detected 15 contaminants in Kings Gate Club's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Kings Gate Club's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Lead, Nitrate, Fluoride, and others. The full list with the level and data source for each is above.
How many people does Kings Gate Club serve?
Kings Gate Club reports serving 838 people in Florida, per its EPA record.
Has Kings Gate Club had any water quality violations?
The EPA has 13 violations on file for Kings Gate Club, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.