Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Unaddressed | 2025-02-01 |
| MCL | Health-based | Resolved | 1988-03-01 → 1991-02-28 |
| MCL | Health-based | Resolved | 1988-03-01 → 1991-02-28 |
| MCL | Health-based | Resolved | 1988-03-01 → 1991-02-28 |
| MCL | Health-based | Resolved | 1988-03-01 → 1991-02-28 |
| MCL | Health-based | Resolved | 1988-03-01 → 1991-02-28 |
| MCL | Health-based | Resolved | 1987-12-01 → 1990-11-30 |
| MCL | Health-based | Resolved | 1987-12-01 → 1990-11-30 |
| MCL | Health-based | Resolved | 1987-12-01 → 1990-11-30 |
| MCL | Health-based | Resolved | 1987-12-01 → 1990-11-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 340 µg/L 3.4% of the EPA limit 10000 µg/L
worst single sample: 480 µg/L | 448/460 | SYR4 | 2012–2019 |
| TTHM | 23.517 µg/L 29% of the EPA limit 80 µg/L
worst single sample: 34.79 µg/L | 207/208 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 20.376 µg/L 34% of the EPA limit 60 µg/L
worst single sample: 29 µg/L | 207/208 | SYR4 | 2012–2019 |
| Fluoride | 323 µg/L 8.1% of the EPA limit 4000 µg/L
worst single sample: 340 µg/L | 115/115 | SYR4 | 2012–2019 |
| Copper | 24.7 µg/L 1.9% of the EPA limit 1300 µg/L
worst single sample: 60 µg/L | 54/219 | SYR4 | 2012–2019 |
| Nitrite | 177 µg/L 18% of the EPA limit 1000 µg/L
worst single sample: 440 µg/L | 47/253 | SYR4 | 2012–2019 |
| Barium | 18.75 µg/L 0.9% of the EPA limit 2000 µg/L
worst single sample: 20 µg/L | 46/47 | SYR4 | 2012–2019 |
| Combined Uranium | 1.02512 µg/L 3.4% of the EPA limit 30 µg/L
worst single sample: 2.384 µg/L | 37/56 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 5.155 pCi/L 34% of the EPA limit 15 pCi/L
worst single sample: 6.1 pCi/L | 28/37 | SYR4 | 2012–2017 |
| Arsenic | 1.495 µg/L 15% of the EPA limit 10 µg/L
worst single sample: 5 µg/L | 22/57 | SYR4 | 2012–2019 |
| Selenium | 2.95 µg/L 5.9% of the EPA limit 50 µg/L
worst single sample: 4.4 µg/L | 11/56 | SYR4 | 2012–2019 |
| Lead | 4.495 µg/L 30% of the EPA limit 15 µg/L
worst single sample: 4.9 µg/L | 10/226 | SYR4 | 2012–2019 |
| Chromium | 8.2 µg/L 8.2% of the EPA limit 100 µg/L
worst single sample: 8.4 µg/L | 9/58 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 6/6 | LCR | 2003 |
| Cyanide | 19.59 µg/L 9.8% of the EPA limit 200 µg/L
worst single sample: 21 µg/L | 3/58 | SYR4 | 2012–2019 |
| Antimony, Total | 1.095 µg/L 18% of the EPA limit 6 µg/L
worst single sample: 1.1 µg/L | 2/63 | SYR4 | 2012–2019 |
| Benzo(A)Pyrene | 0.0200 µg/L 10% of the EPA limit 0.2000 µg/L | 1/61 | SYR4 | 2012–2019 |
| Beryllium, Total | 0.2000 µg/L 5% of the EPA limit 4 µg/L | 1/57 | SYR4 | 2012–2019 |
| Dalapon | 0.3600 µg/L 0.2% of the EPA limit 200 µg/L | 1/57 | SYR4 | 2012–2019 |
| Di(2-ethylhexyl) Adipate | 0.2000 µg/L 0.1% of the EPA limit 400 µg/L | 1/61 | SYR4 | 2012–2019 |
| Mercury | 0.1000 µg/L 5% of the EPA limit 2 µg/L | 1/58 | SYR4 | 2012–2019 |
| Thallium, Total | 0.5000 µg/L 25% of the EPA limit 2 µg/L | 1/53 | SYR4 | 2012–2019 |
49 contaminants tested, none detected
Utility contact
Frequently asked questions about Tampa Bay Water -Cypress Creek
Is Tampa Bay Water -Cypress Creek tap water safe to drink?
EPA monitoring detected 22 contaminants in Tampa Bay Water -Cypress Creek's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Tampa Bay Water -Cypress Creek's water?
EPA monitoring detected Nitrate, TTHM, Total Haloacetic Acids (HAA5), Fluoride, Copper, and others. The full list with the level and data source for each is above.
How many people does Tampa Bay Water -Cypress Creek serve?
Tampa Bay Water -Cypress Creek reports serving 25 people in Florida, per its EPA record.
Has Tampa Bay Water -Cypress Creek had any water quality violations?
The EPA has 25 violations on file for Tampa Bay Water -Cypress Creek, of which 18 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.