← Florida

Tap water quality report

Hillcrest Estates, Inc.

EPA monitoring tested this supplier for 69 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
17
detected
130
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Pasco

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
11
violations on file
1
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2025-12-01 → 2025-12-31
MON Monitoring Resolved 2025-12-01 → 2025-12-31
MR Monitoring Resolved 2024-01-01 → 2024-12-31
MR Monitoring Resolved 2009-07-01 → 2009-09-30
MR Monitoring Resolved 2009-07-01 → 2009-09-30
MR Monitoring Unaddressed 2007-01-01
MR Monitoring Archived 1984-10-01 → 1987-09-30
MR Monitoring Archived 1984-10-01 → 1987-09-30
MR Monitoring Archived 1984-10-01 → 1987-09-30
MR Monitoring Archived 1984-10-01 → 1987-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2000 µg/L 20%
of the EPA limit 10000 µg/L
16/18 SYR4 2012–2019
Lead
0.0011 mg/L 7.3%
of the EPA limit 0.0150 mg/L
13/13 LCR 2024
Fluoride
208.15 µg/L 5.2%
of the EPA limit 4000 µg/L
worst single sample: 223 µg/L
4/5 SYR4 2012–2018
TTHM
71.385 µg/L 89%
of the EPA limit 80 µg/L
worst single sample: 77.1 µg/L
4/4 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
26.695 µg/L 44%
of the EPA limit 60 µg/L
worst single sample: 28 µg/L
4/4 SYR4 2012–2018
Barium
15.92 µg/L 0.8%
of the EPA limit 2000 µg/L
worst single sample: 16 µg/L
3/3 SYR4 2012–2018
Copper
10.56 µg/L 0.8%
of the EPA limit 1300 µg/L
worst single sample: 11 µg/L
3/3 SYR4 2012–2018
Lead
0.2900 µg/L 1.9%
of the EPA limit 15 µg/L
worst single sample: 0.3000 µg/L
3/3 SYR4 2012–2018
Antimony, Total
2.005 µg/L 33%
of the EPA limit 6 µg/L
worst single sample: 2.1 µg/L
2/3 SYR4 2012–2018
Arsenic
3.525 µg/L 35%
of the EPA limit 10 µg/L
worst single sample: 3.6 µg/L
2/3 SYR4 2012–2018
Chromium
2.135 µg/L 2.1%
of the EPA limit 100 µg/L
worst single sample: 2.2 µg/L
2/3 SYR4 2012–2018
Nitrite
152.945 µg/L 15%
of the EPA limit 1000 µg/L
worst single sample: 156 µg/L
2/9 SYR4 2012–2019
Selenium
1.09 µg/L 2.2%
of the EPA limit 50 µg/L
worst single sample: 1.1 µg/L
2/3 SYR4 2012–2018
Beryllium, Total
0.2000 µg/L 5%
of the EPA limit 4 µg/L
1/3 SYR4 2012–2018
Cadmium
0.2000 µg/L 4%
of the EPA limit 5 µg/L
1/3 SYR4 2012–2018
Combined Uranium
1.7284 µg/L 5.8%
of the EPA limit 30 µg/L
1/1 SYR4 2018
Dalapon
0.8600 µg/L 0.4%
of the EPA limit 200 µg/L
1/3 SYR4 2012–2018
52 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAtrazineBhc-GammaBenzeneBenzo(A)PyreneChlorobenzeneCyanideCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PAULA FRENETTE

Frequently asked questions about Hillcrest Estates, Inc.

Is Hillcrest Estates, Inc. tap water safe to drink?

EPA monitoring detected 17 contaminants in Hillcrest Estates, Inc.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Hillcrest Estates, Inc.'s water?

EPA monitoring detected Nitrate, Lead, Fluoride, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Hillcrest Estates, Inc. serve?

Hillcrest Estates, Inc. reports serving 130 people in Florida, per its EPA record.

Has Hillcrest Estates, Inc. had any water quality violations?

The EPA has 11 violations on file for Hillcrest Estates, Inc., of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.