← Florida

Tap water quality report

Spruce Creek North

EPA monitoring tested this supplier for 99 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

99
contaminants tested
15
detected
7,467
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Marion

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
13
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2015-01-01 → 2015-12-31
MR Monitoring Resolved 2015-01-01 → 2015-12-31
MR Monitoring Resolved 2015-01-01 → 2015-12-31
MR Monitoring Resolved 2015-01-01 → 2015-12-31
MR Monitoring Resolved 2015-01-01 → 2015-12-31
MR Monitoring Resolved 2015-01-01 → 2015-12-31
MR Monitoring Resolved 2015-01-01 → 2015-12-31
MR Monitoring Resolved 2015-01-01 → 2015-12-31
MR Monitoring Resolved 2015-01-01 → 2015-12-31
MR Monitoring Resolved 2015-01-01 → 2015-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0078 µg/L 2/2 2023
Pfpea 0.0049 µg/L 2/2 2023
Pfhxa 0.0038 µg/L 1/2 2023
PFOA 0.0041 µg/L 1/2 2023
PFOS 0.0084 µg/L 1/2 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
3030 µg/L 30%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0049 mg/L 33%
of the EPA limit 0.0150 mg/L
14/14 LCR 2023
Total Haloacetic Acids (HAA5)
4.11 µg/L 6.9%
of the EPA limit 60 µg/L
worst single sample: 4.2 µg/L
4/7 SYR4 2014–2019
TTHM
4.157 µg/L 5.2%
of the EPA limit 80 µg/L
worst single sample: 4.19 µg/L
3/7 SYR4 2014–2019
Arsenic
0.2000 µg/L 2%
of the EPA limit 10 µg/L
2/2 SYR4 2014–2017
Barium
5.775 µg/L 0.3%
of the EPA limit 2000 µg/L
worst single sample: 5.8 µg/L
2/2 SYR4 2014–2017
Copper
5.885 µg/L 0.5%
of the EPA limit 1300 µg/L
worst single sample: 6.1 µg/L
2/2 SYR4 2014–2017
Chromium
1.88 µg/L 1.9%
of the EPA limit 100 µg/L
worst single sample: 1.9 µg/L
2/2 SYR4 2014–2017
Selenium
1.785 µg/L 3.6%
of the EPA limit 50 µg/L
worst single sample: 1.8 µg/L
2/2 SYR4 2014–2017
Combined Uranium
0.7450 µg/L 2.5%
of the EPA limit 30 µg/L
1/1 SYR4 2017
84 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TONY CUNNINGHAM
Phone
352-307-4626

Frequently asked questions about Spruce Creek North

Is Spruce Creek North tap water safe to drink?

EPA monitoring detected 15 contaminants in Spruce Creek North's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Spruce Creek North's water?

EPA monitoring detected Nitrate, Lead, Total Haloacetic Acids (HAA5), TTHM, Arsenic, and others. The full list with the level and data source for each is above.

How many people does Spruce Creek North serve?

Spruce Creek North reports serving 7,467 people in Florida, per its EPA record.

Has Spruce Creek North had any water quality violations?

The EPA has 13 violations on file for Spruce Creek North, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.