← Florida

Tap water quality report

Bud Well #7 Wtp

EPA monitoring tested this supplier for 69 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
16
detected
25
people served
1
health-based violations
Water source
SWP
Ownership
Private
Counties served
Hillsborough

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
5
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2025-02-01
MON Monitoring Archived 2025-11-01 → 2025-11-30
MON Monitoring Archived 2025-10-01 → 2025-10-31
MON Monitoring Archived 2025-06-01 → 2025-06-30
RPT Monitoring Unaddressed 2025-02-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
3239 µg/L 32%
of the EPA limit 10000 µg/L
worst single sample: 3740 µg/L
112/112 SYR4 2012–2019
TTHM
19.3195 µg/L 24%
of the EPA limit 80 µg/L
worst single sample: 25.44 µg/L
32/32 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
17.2365 µg/L 29%
of the EPA limit 60 µg/L
worst single sample: 20.66 µg/L
28/32 SYR4 2012–2019
Fluoride
342.5 µg/L 8.6%
of the EPA limit 4000 µg/L
worst single sample: 350 µg/L
26/26 SYR4 2012–2019
Barium
14.45 µg/L 0.7%
of the EPA limit 2000 µg/L
worst single sample: 15 µg/L
12/12 SYR4 2012–2019
Copper
19.4 µg/L 1.5%
of the EPA limit 1300 µg/L
worst single sample: 23 µg/L
9/52 SYR4 2012–2019
Nitrite
52 µg/L 5.2%
of the EPA limit 1000 µg/L
worst single sample: 60 µg/L
9/57 SYR4 2012–2019
Combined Uranium
1.17501 µg/L 3.9%
of the EPA limit 30 µg/L
worst single sample: 1.19796 µg/L
8/11 SYR4 2012–2018
Arsenic
1.18 µg/L 12%
of the EPA limit 10 µg/L
worst single sample: 1.3 µg/L
5/12 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
4.06 pCi/L 27%
of the EPA limit 15 pCi/L
worst single sample: 4.2 pCi/L
5/10 SYR4 2012–2017
Lead
3 µg/L 20%
of the EPA limit 15 µg/L
4/51 SYR4 2012–2019
Cyanide
11.69 µg/L 5.8%
of the EPA limit 200 µg/L
worst single sample: 12 µg/L
2/13 SYR4 2012–2019
Chromium
0.6950 µg/L 0.7%
of the EPA limit 100 µg/L
worst single sample: 0.7000 µg/L
2/13 SYR4 2012–2019
Di(2-ethylhexyl) Adipate
1.6455 µg/L 0.4%
of the EPA limit 400 µg/L
worst single sample: 1.7 µg/L
2/25 SYR4 2012–2018
Antimony, Total
3.2 µg/L 53%
of the EPA limit 6 µg/L
1/13 SYR4 2012–2019
Selenium
0.6000 µg/L 1.2%
of the EPA limit 50 µg/L
1/13 SYR4 2012–2019
53 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RON PARKER
Phone
727-796-2355

Frequently asked questions about Bud Well #7 Wtp

Is Bud Well #7 Wtp tap water safe to drink?

EPA monitoring detected 16 contaminants in Bud Well #7 Wtp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Bud Well #7 Wtp's water?

EPA monitoring detected Nitrate, TTHM, Total Haloacetic Acids (HAA5), Fluoride, Barium, and others. The full list with the level and data source for each is above.

How many people does Bud Well #7 Wtp serve?

Bud Well #7 Wtp reports serving 25 people in Florida, per its EPA record.

Has Bud Well #7 Wtp had any water quality violations?

The EPA has 5 violations on file for Bud Well #7 Wtp, of which 1 is health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.