Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2013-03-01 → 2013-03-31 |
| MCL | Health-based | Resolved | 2013-03-01 → 2013-03-31 |
| MCL | Health-based | Archived | 2003-04-01 → 2003-04-30 |
| MCL | Health-based | Archived | 2003-04-01 → 2003-04-30 |
| MCL | Health-based | Archived | 2003-04-01 → 2003-04-30 |
| MCL | Health-based | Archived | 1992-01-01 → 1995-12-31 |
| MCL | Health-based | Archived | 1992-01-01 → 1995-12-31 |
| MCL | Health-based | Archived | 1991-05-01 → 1991-05-31 |
| MCL | Health-based | Archived | 1991-05-01 → 1991-05-31 |
| MCL | Health-based | Archived | 1991-05-01 → 1991-05-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 54.012 µg/L 68% of the EPA limit 80 µg/L
worst single sample: 72.3 µg/L | 112/112 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 20.2835 µg/L 34% of the EPA limit 60 µg/L
worst single sample: 33.37 µg/L | 112/112 | SYR4 | 2012–2019 |
| Fluoride | 900 µg/L 23% of the EPA limit 4000 µg/L
worst single sample: 1200 µg/L | 47/47 | SYR4 | 2013–2019 |
| Nitrate | 2575 µg/L 26% of the EPA limit 10000 µg/L
worst single sample: 3100 µg/L | 36/36 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 13/13 | LCR | 2023 |
| Combined Uranium | 8.6122 µg/L 29% of the EPA limit 30 µg/L
worst single sample: 8.791 µg/L | 4/4 | SYR4 | 2014–2017 |
| Gross Alpha, Excl. Radon And U | 3.625 pCi/L 24% of the EPA limit 15 pCi/L
worst single sample: 3.7 pCi/L | 4/4 | SYR4 | 2014–2017 |
| Selenium | 6.68 µg/L 13% of the EPA limit 50 µg/L
worst single sample: 6.7 µg/L | 3/4 | SYR4 | 2014–2017 |
| Antimony, Total | 0.2900 µg/L 4.8% of the EPA limit 6 µg/L
worst single sample: 0.3000 µg/L | 2/4 | SYR4 | 2014–2017 |
| Arsenic | 2.325 µg/L 23% of the EPA limit 10 µg/L
worst single sample: 2.4 µg/L | 2/4 | SYR4 | 2014–2017 |
| Barium | 16.9 µg/L 0.8% of the EPA limit 2000 µg/L
worst single sample: 17 µg/L | 2/4 | SYR4 | 2014–2017 |
| Cadmium | 0.2900 µg/L 5.8% of the EPA limit 5 µg/L
worst single sample: 0.3000 µg/L | 2/4 | SYR4 | 2014–2017 |
| Mercury | 0.1000 µg/L 5% of the EPA limit 2 µg/L | 2/4 | SYR4 | 2014–2017 |
| Chromium | 0.6000 µg/L 0.6% of the EPA limit 100 µg/L | 1/4 | SYR4 | 2014–2017 |
| Diquat | 0.9870 µg/L 4.9% of the EPA limit 20 µg/L | 1/14 | SYR4 | 2014–2018 |
| Lead | 0.3000 µg/L 2% of the EPA limit 15 µg/L | 1/4 | SYR4 | 2014–2017 |
| Thallium, Total | 0.2000 µg/L 10% of the EPA limit 2 µg/L | 1/4 | SYR4 | 2014–2017 |
75 contaminants tested, none detected
Utility contact
Frequently asked questions about City of Temple Terrace Utility
Is City of Temple Terrace Utility tap water safe to drink?
EPA monitoring detected 25 contaminants in City of Temple Terrace Utility's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in City of Temple Terrace Utility's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Fluoride, Nitrate, Lead, and others. The full list with the level and data source for each is above.
How many people does City of Temple Terrace Utility serve?
City of Temple Terrace Utility reports serving 31,250 people in Florida, per its EPA record.
Has City of Temple Terrace Utility had any water quality violations?
The EPA has 28 violations on file for City of Temple Terrace Utility, of which 10 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.