EPA monitoring tested this supplier for 100 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

100
contaminants tested
25
detected
31,250
people served
10
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Hillsborough

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

10
health-based violations
28
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2013-03-01 → 2013-03-31
MCL Health-based Resolved 2013-03-01 → 2013-03-31
MCL Health-based Archived 2003-04-01 → 2003-04-30
MCL Health-based Archived 2003-04-01 → 2003-04-30
MCL Health-based Archived 2003-04-01 → 2003-04-30
MCL Health-based Archived 1992-01-01 → 1995-12-31
MCL Health-based Archived 1992-01-01 → 1995-12-31
MCL Health-based Archived 1991-05-01 → 1991-05-31
MCL Health-based Archived 1991-05-01 → 1991-05-31
MCL Health-based Archived 1991-05-01 → 1991-05-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0122 µg/L 4/4 2025
Pfhxa 0.0059 µg/L 4/4 2025
PFHXS 0.0088 µg/L 4/4 2025
PFOA 0.0100 µg/L 4/4 2025
PFOS 0.0195 µg/L 4/4 2025
Pfpea 0.0081 µg/L 4/4 2025
Pfhpa 0.0038 µg/L 3/4 2025
Pfba 0.0058 µg/L 2/4 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
54.012 µg/L 68%
of the EPA limit 80 µg/L
worst single sample: 72.3 µg/L
112/112 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
20.2835 µg/L 34%
of the EPA limit 60 µg/L
worst single sample: 33.37 µg/L
112/112 SYR4 2012–2019
Fluoride
900 µg/L 23%
of the EPA limit 4000 µg/L
worst single sample: 1200 µg/L
47/47 SYR4 2013–2019
Nitrate
2575 µg/L 26%
of the EPA limit 10000 µg/L
worst single sample: 3100 µg/L
36/36 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2023
Combined Uranium
8.6122 µg/L 29%
of the EPA limit 30 µg/L
worst single sample: 8.791 µg/L
4/4 SYR4 2014–2017
Gross Alpha, Excl. Radon And U
3.625 pCi/L 24%
of the EPA limit 15 pCi/L
worst single sample: 3.7 pCi/L
4/4 SYR4 2014–2017
Selenium
6.68 µg/L 13%
of the EPA limit 50 µg/L
worst single sample: 6.7 µg/L
3/4 SYR4 2014–2017
Antimony, Total
0.2900 µg/L 4.8%
of the EPA limit 6 µg/L
worst single sample: 0.3000 µg/L
2/4 SYR4 2014–2017
Arsenic
2.325 µg/L 23%
of the EPA limit 10 µg/L
worst single sample: 2.4 µg/L
2/4 SYR4 2014–2017
Barium
16.9 µg/L 0.8%
of the EPA limit 2000 µg/L
worst single sample: 17 µg/L
2/4 SYR4 2014–2017
Cadmium
0.2900 µg/L 5.8%
of the EPA limit 5 µg/L
worst single sample: 0.3000 µg/L
2/4 SYR4 2014–2017
Mercury
0.1000 µg/L 5%
of the EPA limit 2 µg/L
2/4 SYR4 2014–2017
Chromium
0.6000 µg/L 0.6%
of the EPA limit 100 µg/L
1/4 SYR4 2014–2017
Diquat
0.9870 µg/L 4.9%
of the EPA limit 20 µg/L
1/14 SYR4 2014–2018
Lead
0.3000 µg/L 2%
of the EPA limit 15 µg/L
1/4 SYR4 2014–2017
Thallium, Total
0.2000 µg/L 10%
of the EPA limit 2 µg/L
1/4 SYR4 2014–2017
75 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfdaPfdoaPfeesaPfhpsPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CARLOS BAIA
Phone
813-506-6413

Frequently asked questions about City of Temple Terrace Utility

Is City of Temple Terrace Utility tap water safe to drink?

EPA monitoring detected 25 contaminants in City of Temple Terrace Utility's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Temple Terrace Utility's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Fluoride, Nitrate, Lead, and others. The full list with the level and data source for each is above.

How many people does City of Temple Terrace Utility serve?

City of Temple Terrace Utility reports serving 31,250 people in Florida, per its EPA record.

Has City of Temple Terrace Utility had any water quality violations?

The EPA has 28 violations on file for City of Temple Terrace Utility, of which 10 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.