← Florida

Tap water quality report

Hernando Co Utl-East

EPA monitoring tested this supplier for 100 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

100
contaminants tested
21
detected
9,483
people served
4
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Hernando

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
20
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2010-11-01 → 2010-11-30
MCL Health-based Archived 2005-02-01 → 2005-02-28
MCL Health-based Archived 2005-02-01 → 2005-02-28
MCL Health-based Archived 2005-02-01 → 2005-02-28
MON Monitoring Resolved 2025-03-01 → 2025-03-31
MR Monitoring Resolved 2025-03-01 → 2025-03-31
MON Monitoring Resolved 2025-02-01 → 2025-02-28
MR Monitoring Resolved 2025-02-01 → 2025-02-28
MON Monitoring Resolved 2025-01-01 → 2025-01-31
MR Monitoring Resolved 2025-01-01 → 2025-01-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0110 µg/L 4/10 2025
PFOS 0.0160 µg/L 2/10 2025
PFOA 0.0052 µg/L 1/10 2025
Pfpea 0.0036 µg/L 1/10 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1600 µg/L 16%
of the EPA limit 10000 µg/L
worst single sample: 1700 µg/L
96/106 SYR4 2012–2019
TTHM
64.2845 µg/L 80%
of the EPA limit 80 µg/L
worst single sample: 69.77 µg/L
24/24 SYR4 2014–2019
Fluoride
120 µg/L 3%
of the EPA limit 4000 µg/L
20/26 SYR4 2014–2017
Total Haloacetic Acids (HAA5)
10.444 µg/L 17%
of the EPA limit 60 µg/L
worst single sample: 12.23 µg/L
20/24 SYR4 2014–2019
Copper
17.6 µg/L 1.4%
of the EPA limit 1300 µg/L
worst single sample: 23 µg/L
13/13 SYR4 2014–2017
Lead
0.0017 mg/L 11%
of the EPA limit 0.0150 mg/L
13/13 LCR 2023
Barium
6.25 µg/L 0.3%
of the EPA limit 2000 µg/L
worst single sample: 6.3 µg/L
11/13 SYR4 2014–2017
Arsenic
1.46 µg/L 15%
of the EPA limit 10 µg/L
worst single sample: 1.5 µg/L
9/13 SYR4 2014–2017
Combined Uranium
1.89528 µg/L 6.3%
of the EPA limit 30 µg/L
worst single sample: 2.086 µg/L
5/7 SYR4 2014
Chromium
1.23 µg/L 1.2%
of the EPA limit 100 µg/L
worst single sample: 1.3 µg/L
3/13 SYR4 2014–2017
Mercury
0.5500 µg/L 28%
of the EPA limit 2 µg/L
worst single sample: 0.6000 µg/L
3/13 SYR4 2014–2017
Lead
1.17 µg/L 7.8%
of the EPA limit 15 µg/L
worst single sample: 1.2 µg/L
2/13 SYR4 2014–2017
Antimony, Total
0.4000 µg/L 6.7%
of the EPA limit 6 µg/L
1/13 SYR4 2014–2017
Cadmium
0.8000 µg/L 16%
of the EPA limit 5 µg/L
1/13 SYR4 2014–2017
Nitrite
20 µg/L 2%
of the EPA limit 1000 µg/L
1/53 SYR4 2012–2019
Selenium
0.6000 µg/L 1.2%
of the EPA limit 50 µg/L
1/13 SYR4 2014–2017
Thallium, Total
0.1000 µg/L 5%
of the EPA limit 2 µg/L
1/13 SYR4 2014–2017
79 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JOSEPH FRETTO
Phone
352-754-4490

Frequently asked questions about Hernando Co Utl-East

Is Hernando Co Utl-East tap water safe to drink?

EPA monitoring detected 21 contaminants in Hernando Co Utl-East's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Hernando Co Utl-East's water?

EPA monitoring detected Nitrate, TTHM, Fluoride, Total Haloacetic Acids (HAA5), Copper, and others. The full list with the level and data source for each is above.

How many people does Hernando Co Utl-East serve?

Hernando Co Utl-East reports serving 9,483 people in Florida, per its EPA record.

Has Hernando Co Utl-East had any water quality violations?

The EPA has 20 violations on file for Hernando Co Utl-East, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.