Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2021-04-01 → 2021-06-30 |
| MCL | Health-based | Resolved | 2021-04-01 → 2021-06-30 |
| MCL | Health-based | Resolved | 2021-01-01 → 2021-03-31 |
| MCL | Health-based | Resolved | 2021-01-01 → 2021-03-31 |
| MCL | Health-based | Resolved | 2020-10-01 → 2020-12-31 |
| MCL | Health-based | Resolved | 2020-10-01 → 2020-12-31 |
| MCL | Health-based | Resolved | 2020-07-01 → 2020-09-30 |
| MCL | Health-based | Resolved | 2020-07-01 → 2020-09-30 |
| MCL | Health-based | Resolved | 2020-07-01 → 2020-09-30 |
| MCL | Health-based | Archived | 2007-06-01 → 2007-06-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Lead | 0.0074 mg/L 49% of the EPA limit 0.0150 mg/L | 24/24 | LCR | 2025 |
| Nitrate | 340 µg/L 3.4% of the EPA limit 10000 µg/L | 12/20 | SYR4 | 2012–2019 |
| Fluoride | 167.5 µg/L 4.2% of the EPA limit 4000 µg/L
worst single sample: 180 µg/L | 6/6 | SYR4 | 2012–2018 |
| TTHM | 62.32 µg/L 78% of the EPA limit 80 µg/L
worst single sample: 63.5 µg/L | 5/8 | SYR4 | 2012–2019 |
| Barium | 69.8 µg/L 3.5% of the EPA limit 2000 µg/L
worst single sample: 74 µg/L | 3/3 | SYR4 | 2012–2018 |
| Copper | 18.5 µg/L 1.4% of the EPA limit 1300 µg/L
worst single sample: 19 µg/L | 3/3 | SYR4 | 2012–2018 |
| Dalapon | 7.55 µg/L 3.8% of the EPA limit 200 µg/L
worst single sample: 7.8 µg/L | 3/6 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 2.699 µg/L 4.5% of the EPA limit 60 µg/L
worst single sample: 2.7 µg/L | 3/8 | SYR4 | 2012–2019 |
| Arsenic | 1.455 µg/L 15% of the EPA limit 10 µg/L
worst single sample: 1.5 µg/L | 2/3 | SYR4 | 2012–2018 |
| Lead | 0.6900 µg/L 4.6% of the EPA limit 15 µg/L
worst single sample: 0.7000 µg/L | 2/3 | SYR4 | 2012–2018 |
| Di(2-ethylhexyl) Phthalate | 0.9500 µg/L 16% of the EPA limit 6 µg/L | 1/6 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 3.37 pCi/L 22% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2015 |
| Hexachlorocyclopentadiene | 0.0320 µg/L 0.1% of the EPA limit 50 µg/L | 1/2 | SYR4 | 2012–2018 |
56 contaminants tested, none detected
Utility contact
Frequently asked questions about Big Cypress Park Headquarters
Is Big Cypress Park Headquarters tap water safe to drink?
EPA monitoring detected 13 contaminants in Big Cypress Park Headquarters's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Big Cypress Park Headquarters's water?
EPA monitoring detected Lead, Nitrate, Fluoride, TTHM, Barium, and others. The full list with the level and data source for each is above.
How many people does Big Cypress Park Headquarters serve?
Big Cypress Park Headquarters reports serving 50 people in Florida, per its EPA record.
Has Big Cypress Park Headquarters had any water quality violations?
The EPA has 47 violations on file for Big Cypress Park Headquarters, of which 36 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.