← Florida

Tap water quality report

Lee Cypress Co-Op

EPA monitoring tested this supplier for 69 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
14
detected
82
people served
73
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Collier

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

73
health-based violations
260
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2022-07-01 → 2022-09-30
MCL Health-based Archived 2022-04-01 → 2022-06-30
MCL Health-based Archived 2022-04-01 → 2022-06-30
MCL Health-based Archived 2022-01-01 → 2022-03-31
MCL Health-based Archived 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2021-10-01 → 2021-12-31
MCL Health-based Resolved 2021-10-01 → 2021-12-31
MCL Health-based Resolved 2021-10-01 → 2021-12-31
MCL Health-based Resolved 2021-10-01 → 2021-12-31
MCL Health-based Resolved 2021-10-01 → 2021-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0046 mg/L 31%
of the EPA limit 0.0150 mg/L
27/27 LCR 2025
Nitrate
210 µg/L 2.1%
of the EPA limit 10000 µg/L
12/20 SYR4 2012–2019
TTHM
86.15 µg/L 108%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 110 µg/L
7/7 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
38.29 µg/L 64%
of the EPA limit 60 µg/L
worst single sample: 43.9 µg/L
7/7 SYR4 2012–2018
Arsenic
0.9700 µg/L 9.7%
of the EPA limit 10 µg/L
worst single sample: 1 µg/L
3/3 SYR4 2012–2018
Barium
24.9 µg/L 1.2%
of the EPA limit 2000 µg/L
worst single sample: 25 µg/L
3/3 SYR4 2012–2018
Copper
30.8 µg/L 2.4%
of the EPA limit 1300 µg/L
worst single sample: 33 µg/L
3/3 SYR4 2012–2018
Nitrite
28 µg/L 2.8%
of the EPA limit 1000 µg/L
worst single sample: 30 µg/L
3/10 SYR4 2012–2019
Dalapon
3.45 µg/L 1.7%
of the EPA limit 200 µg/L
worst single sample: 3.5 µg/L
2/7 SYR4 2012–2016
Fluoride
133 µg/L 3.3%
of the EPA limit 4000 µg/L
2/6 SYR4 2012–2018
Cyanide
25 µg/L 13%
of the EPA limit 200 µg/L
1/3 SYR4 2012–2018
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
1/3 SYR4 2012–2018
Lead
1 µg/L 6.7%
of the EPA limit 15 µg/L
1/3 SYR4 2012–2018
Selenium
2 µg/L 4%
of the EPA limit 50 µg/L
1/3 SYR4 2012–2018
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GARY DEREMER
Phone
727-848-8292

Frequently asked questions about Lee Cypress Co-Op

Is Lee Cypress Co-Op tap water safe to drink?

EPA monitoring detected 14 contaminants in Lee Cypress Co-Op's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lee Cypress Co-Op's water?

EPA monitoring detected Lead, Nitrate, TTHM, Total Haloacetic Acids (HAA5), Arsenic, and others. The full list with the level and data source for each is above.

How many people does Lee Cypress Co-Op serve?

Lee Cypress Co-Op reports serving 82 people in Florida, per its EPA record.

Has Lee Cypress Co-Op had any water quality violations?

The EPA has 260 violations on file for Lee Cypress Co-Op, of which 73 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.