Tap water quality report

Pelican Lake Water Plant

EPA monitoring tested this supplier for 69 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
13
detected
222
people served
2
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Palm Beach

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
48
violations on file
3
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MR Monitoring Resolved 2024-10-01 → 2024-10-31
MON Monitoring Resolved 2024-10-01 → 2024-10-31
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
MR Monitoring Resolved 2024-04-01 → 2024-04-30
MON Monitoring Resolved 2024-04-01 → 2024-04-30
MR Monitoring Resolved 2023-11-01 → 2023-11-30
MON Monitoring Resolved 2023-11-01 → 2023-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
98.016 µg/L 123%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 110 µg/L
15/17 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
31.02 µg/L 52%
of the EPA limit 60 µg/L
worst single sample: 31.72 µg/L
15/16 SYR4 2012–2019
Lead
0.0100 mg/L 67%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
Fluoride
150 µg/L 3.8%
of the EPA limit 4000 µg/L
4/4 SYR4 2012–2018
Nitrate
170 µg/L 1.7%
of the EPA limit 10000 µg/L
4/12 SYR4 2012–2019
Barium
22.46 µg/L 1.1%
of the EPA limit 2000 µg/L
worst single sample: 22.6 µg/L
2/2 SYR4 2012–2018
Antimony, Total
0.1000 µg/L 1.7%
of the EPA limit 6 µg/L
1/2 SYR4 2012–2018
Arsenic
1.1 µg/L 11%
of the EPA limit 10 µg/L
1/2 SYR4 2012–2018
Copper
36 µg/L 2.8%
of the EPA limit 1300 µg/L
1/2 SYR4 2012–2018
Chromium
1.4 µg/L 1.4%
of the EPA limit 100 µg/L
1/2 SYR4 2012–2018
Lead
0.2000 µg/L 1.3%
of the EPA limit 15 µg/L
1/2 SYR4 2012–2018
Mercury
0.6000 µg/L 30%
of the EPA limit 2 µg/L
1/2 SYR4 2012–2018
Nitrite
50 µg/L 5%
of the EPA limit 1000 µg/L
1/6 SYR4 2012–2019
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ROBERT SCHESTIEL
Phone
832-521-1880

Frequently asked questions about Pelican Lake Water Plant

Is Pelican Lake Water Plant tap water safe to drink?

EPA monitoring detected 13 contaminants in Pelican Lake Water Plant's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pelican Lake Water Plant's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Lead, Fluoride, Nitrate, and others. The full list with the level and data source for each is above.

How many people does Pelican Lake Water Plant serve?

Pelican Lake Water Plant reports serving 222 people in Florida, per its EPA record.

Has Pelican Lake Water Plant had any water quality violations?

The EPA has 48 violations on file for Pelican Lake Water Plant, of which 2 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.