Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MON | Monitoring | Resolved | 2024-06-01 → 2024-06-30 |
| MON | Monitoring | Resolved | 2024-06-01 → 2024-06-30 |
| MR | Monitoring | Resolved | 2023-01-01 → 2023-12-31 |
| RPT | Monitoring | Resolved | 2018-02-01 |
| RPT | Monitoring | Resolved | 2018-02-01 |
| MR | Monitoring | Resolved | 2018-01-01 |
| Other | Monitoring | Resolved | 2017-07-01 |
| Other | Monitoring | Resolved | 2017-07-01 |
| MR | Monitoring | Unaddressed | 2015-01-01 |
| MR | Monitoring | Resolved | 2011-04-01 → 2011-04-30 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 63.09 µg/L 79% of the EPA limit 80 µg/L
worst single sample: 81.2 µg/L | 114/114 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 50.92 µg/L 85% of the EPA limit 60 µg/L
worst single sample: 101 µg/L | 113/113 | SYR4 | 2012–2019 |
| Nitrate | 212.5 µg/L 2.1% of the EPA limit 10000 µg/L
worst single sample: 220 µg/L | 26/32 | SYR4 | 2012–2019 |
| Lead | 0.00090 mg/L 6% of the EPA limit 0.0150 mg/L | 17/17 | LCR | 2023 |
| Fluoride | 197.5 µg/L 4.9% of the EPA limit 4000 µg/L
worst single sample: 200 µg/L | 6/6 | SYR4 | 2014–2017 |
| Barium | 4.78 µg/L 0.2% of the EPA limit 2000 µg/L
worst single sample: 4.9 µg/L | 4/4 | SYR4 | 2014–2017 |
| Copper | 0.8900 µg/L 0.1% of the EPA limit 1300 µg/L
worst single sample: 0.9000 µg/L | 2/4 | SYR4 | 2014–2017 |
| Dichloromethane | 0.9670 µg/L 19% of the EPA limit 5 µg/L
worst single sample: 0.9900 µg/L | 2/12 | SYR4 | 2014–2019 |
| Dalapon | 1.4725 µg/L 0.7% of the EPA limit 200 µg/L
worst single sample: 1.5 µg/L | 2/8 | SYR4 | 2014–2017 |
| Nitrite | 59.5 µg/L 5.9% of the EPA limit 1000 µg/L
worst single sample: 60 µg/L | 2/17 | SYR4 | 2012–2019 |
| Hexachlorocyclopentadiene | 0.0320 µg/L 0.1% of the EPA limit 50 µg/L | 1/8 | SYR4 | 2014–2017 |
82 contaminants tested, none detected
Utility contact
Frequently asked questions about Palm Springs, Village of
Is Palm Springs, Village of tap water safe to drink?
EPA monitoring detected 19 contaminants in Palm Springs, Village of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Palm Springs, Village of's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Nitrate, Lead, Fluoride, and others. The full list with the level and data source for each is above.
How many people does Palm Springs, Village of serve?
Palm Springs, Village of reports serving 32,467 people in Florida, per its EPA record.
Has Palm Springs, Village of had any water quality violations?
The EPA has 16 violations on file for Palm Springs, Village of, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.