← Florida

Tap water quality report

Vc/Southwest wtp-2

EPA monitoring tested this supplier for 98 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

98
contaminants tested
12
detected
3,842
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Volusia

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
11
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2011-10-07
Other Monitoring Resolved 2011-10-07
MR Monitoring Resolved 2011-08-01 → 2011-08-31
MR Monitoring Resolved 2011-08-01 → 2011-08-31
MR Monitoring Resolved 2011-08-01 → 2011-08-31
MR Monitoring Resolved 2011-08-01 → 2011-08-31
MR Monitoring Resolved 2011-08-01 → 2011-08-31
MR Monitoring Archived 1994-07-01 → 1994-07-31
MR Monitoring Archived 1991-08-01 → 1991-08-31
MR Monitoring Archived 1991-07-01 → 1991-07-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0052 µg/L 2/2 2024
Pfhxa 0.0033 µg/L 2/2 2024
Pfpea 0.0050 µg/L 2/2 2024
Pfhpa 0.0030 µg/L 1/2 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
83.61 µg/L 105%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 84.8 µg/L
38/38 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
27.65 µg/L 46%
of the EPA limit 60 µg/L
worst single sample: 54.7 µg/L
38/38 SYR4 2012–2019
Nitrate
940 µg/L 9.4%
of the EPA limit 10000 µg/L
16/18 SYR4 2012–2019
Lead
0.0011 mg/L 7.3%
of the EPA limit 0.0150 mg/L
12/12 LCR 2023
Fluoride
94 µg/L 2.4%
of the EPA limit 4000 µg/L
4/4 SYR4 2014–2017
Barium
15.9 µg/L 0.8%
of the EPA limit 2000 µg/L
worst single sample: 16 µg/L
2/2 SYR4 2014–2017
Copper
9.57 µg/L 0.7%
of the EPA limit 1300 µg/L
worst single sample: 10 µg/L
2/2 SYR4 2014–2017
Arsenic
1.4 µg/L 14%
of the EPA limit 10 µg/L
1/2 SYR4 2014–2017
86 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPfdaPfdoaPfeesaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ROBERT BEEDLE
Phone
386-822-6465

Frequently asked questions about Vc/Southwest wtp-2

Is Vc/Southwest wtp-2 tap water safe to drink?

EPA monitoring detected 12 contaminants in Vc/Southwest wtp-2's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Vc/Southwest wtp-2's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Nitrate, Lead, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Vc/Southwest wtp-2 serve?

Vc/Southwest wtp-2 reports serving 3,842 people in Florida, per its EPA record.

Has Vc/Southwest wtp-2 had any water quality violations?

The EPA has 11 violations on file for Vc/Southwest wtp-2, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.