← Florida

Tap water quality report

Deltona Water

EPA monitoring tested this supplier for 98 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

98
contaminants tested
18
detected
81,006
people served
40
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Volusia

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

40
health-based violations
60
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2015-01-01 → 2015-03-31
MCL Health-based Resolved 2015-01-01 → 2015-03-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-07-01 → 2014-09-30
MCL Health-based Resolved 2014-07-01 → 2014-09-30
MCL Health-based Resolved 2014-07-01 → 2014-09-30
MCL Health-based Resolved 2014-04-01 → 2014-06-30
MCL Health-based Resolved 2014-04-01 → 2014-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0107 µg/L 15/22 2024
PFOS 0.0108 µg/L 13/22 2024
Pfpea 0.0064 µg/L 12/22 2024
PFHXS 0.0065 µg/L 9/22 2024
PFOA 0.0068 µg/L 8/22 2024
Pfhxa 0.0050 µg/L 7/22 2024
Pfhpa 0.0032 µg/L 2/22 2024
Pfba 0.0058 µg/L 1/22 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
132.41 µg/L 166%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 217.87 µg/L
138/138 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
60.2 µg/L 100%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 91.3 µg/L
136/138 SYR4 2012–2019
Nitrate
2920 µg/L 29%
of the EPA limit 10000 µg/L
worst single sample: 3400 µg/L
128/242 SYR4 2012–2019
Barium
37.35 µg/L 1.9%
of the EPA limit 2000 µg/L
worst single sample: 38 µg/L
26/26 SYR4 2014–2017
Fluoride
179 µg/L 4.5%
of the EPA limit 4000 µg/L
worst single sample: 180 µg/L
22/52 SYR4 2014–2017
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2023
Copper
5.475 µg/L 0.4%
of the EPA limit 1300 µg/L
worst single sample: 5.5 µg/L
6/26 SYR4 2014–2017
Nitrite
199.5 µg/L 20%
of the EPA limit 1000 µg/L
worst single sample: 210 µg/L
4/122 SYR4 2012–2019
Arsenic
2.785 µg/L 28%
of the EPA limit 10 µg/L
worst single sample: 2.9 µg/L
2/26 SYR4 2014–2017
Cyanide
7.4 µg/L 3.7%
of the EPA limit 200 µg/L
1/26 SYR4 2014–2017
80 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfdaPfdoaPfeesaPfhpsPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
UTILITY DIRECTOR / DELTONA WATER
Phone
386-878-8950

Frequently asked questions about Deltona Water

Is Deltona Water tap water safe to drink?

EPA monitoring detected 18 contaminants in Deltona Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Deltona Water's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Nitrate, Barium, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Deltona Water serve?

Deltona Water reports serving 81,006 people in Florida, per its EPA record.

Has Deltona Water had any water quality violations?

The EPA has 60 violations on file for Deltona Water, of which 40 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.