← Florida

Tap water quality report

Seminole County Southeast

EPA monitoring tested this supplier for 100 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

100
contaminants tested
13
detected
70,040
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Seminole

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
24
violations on file
1
still open
ViolationTypeStatusPeriod
MON Monitoring Archived 2025-08-01 → 2025-08-31
MR Monitoring Archived 2025-08-01 → 2025-08-31
MR Monitoring Unaddressed 2025-05-01
Other Monitoring Resolved 2018-07-01
MR Monitoring Resolved 2013-01-01 → 2013-12-31
MR Monitoring Resolved 2013-01-01 → 2013-12-31
Other Monitoring Resolved 2007-06-21
Other Monitoring Resolved 2007-06-21
MR Monitoring Resolved 2007-01-01 → 2007-03-31
MR Monitoring Resolved 2007-01-01 → 2007-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
88.77 µg/L 111%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 123.39 µg/L
126/127 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
55.1275 µg/L 92%
of the EPA limit 60 µg/L
worst single sample: 78.47 µg/L
126/126 SYR4 2012–2019
Nitrate
495 µg/L 5%
of the EPA limit 10000 µg/L
worst single sample: 560 µg/L
26/50 SYR4 2012–2019
Lead
0.0012 mg/L 8%
of the EPA limit 0.0150 mg/L
14/14 LCR 2023
Fluoride
960 µg/L 24%
of the EPA limit 4000 µg/L
10/10 SYR4 2014–2017
Barium
9.7 µg/L 0.5%
of the EPA limit 2000 µg/L
5/5 SYR4 2014–2017
Copper
7.63 µg/L 0.6%
of the EPA limit 1300 µg/L
worst single sample: 7.9 µg/L
4/5 SYR4 2014–2017
Dalapon
1.59 µg/L 0.8%
of the EPA limit 200 µg/L
worst single sample: 1.6 µg/L
3/13 SYR4 2014–2017
Arsenic
0.1000 µg/L 1%
of the EPA limit 10 µg/L
1/5 SYR4 2014–2017
Di(2-ethylhexyl) Phthalate
1.9 µg/L 32%
of the EPA limit 6 µg/L
1/16 SYR4 2014–2017
Hexachlorocyclopentadiene
0.0160 µg/L 0%
of the EPA limit 50 µg/L
1/10 SYR4 2014–2017
Lead
7.7 µg/L 51%
of the EPA limit 15 µg/L
1/5 SYR4 2014–2017
Selenium
1 µg/L 2%
of the EPA limit 50 µg/L
1/5 SYR4 2014–2017
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DALLAS SMITH
Phone
407-665-2759

Frequently asked questions about Seminole County Southeast

Is Seminole County Southeast tap water safe to drink?

EPA monitoring detected 13 contaminants in Seminole County Southeast's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Seminole County Southeast's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Nitrate, Lead, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Seminole County Southeast serve?

Seminole County Southeast reports serving 70,040 people in Florida, per its EPA record.

Has Seminole County Southeast had any water quality violations?

The EPA has 24 violations on file for Seminole County Southeast, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.