← Florida

Tap water quality report

Santa Fe Hills Subdivision

EPA monitoring tested this supplier for 70 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

70
contaminants tested
15
detected
200
people served
7
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Alachua

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

7
health-based violations
77
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2025-02-01
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MCL Health-based Resolved 2010-07-01 → 2010-07-31
MCL Health-based Resolved 1996-03-01 → 1996-03-31
MCL Health-based Archived 1996-03-01 → 1996-03-31
RPT Monitoring Unaddressed 2025-02-01
MON Monitoring Resolved 2023-09-01 → 2023-09-30
MR Monitoring Unaddressed 2022-01-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0014 mg/L 9.3%
of the EPA limit 0.0150 mg/L
20/20 LCR 2023
Nitrate
3400 µg/L 34%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Fluoride
202 µg/L 5.1%
of the EPA limit 4000 µg/L
worst single sample: 210 µg/L
5/6 SYR4 2012–2018
Barium
11.33 µg/L 0.6%
of the EPA limit 2000 µg/L
worst single sample: 12 µg/L
3/3 SYR4 2012–2018
Copper
4.48 µg/L 0.3%
of the EPA limit 1300 µg/L
worst single sample: 4.5 µg/L
3/3 SYR4 2012–2018
Chromium
8.47 µg/L 8.5%
of the EPA limit 100 µg/L
worst single sample: 9.3 µg/L
3/3 SYR4 2012–2018
TTHM
2.027 µg/L 2.5%
of the EPA limit 80 µg/L
worst single sample: 2.1 µg/L
3/4 SYR4 2012–2018
Arsenic
0.9850 µg/L 9.9%
of the EPA limit 10 µg/L
worst single sample: 1 µg/L
2/3 SYR4 2012–2018
Antimony, Total
0.4000 µg/L 6.7%
of the EPA limit 6 µg/L
1/3 SYR4 2012–2018
Combined Uranium
0.8046 µg/L 2.7%
of the EPA limit 30 µg/L
1/1 SYR4 2018
Di(2-ethylhexyl) Phthalate
0.6900 µg/L 12%
of the EPA limit 6 µg/L
1/12 SYR4 2012–2018
Lead
0.2000 µg/L 1.3%
of the EPA limit 15 µg/L
1/3 SYR4 2012–2018
Mercury
0.1000 µg/L 5%
of the EPA limit 2 µg/L
1/3 SYR4 2012–2018
Selenium
2 µg/L 4%
of the EPA limit 50 µg/L
1/3 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
1.06 µg/L 1.8%
of the EPA limit 60 µg/L
1/4 SYR4 2012–2018
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
KENNETH FAIR
Phone
352-374-5245

Frequently asked questions about Santa Fe Hills Subdivision

Is Santa Fe Hills Subdivision tap water safe to drink?

EPA monitoring detected 15 contaminants in Santa Fe Hills Subdivision's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Santa Fe Hills Subdivision's water?

EPA monitoring detected Lead, Nitrate, Fluoride, Barium, Copper, and others. The full list with the level and data source for each is above.

How many people does Santa Fe Hills Subdivision serve?

Santa Fe Hills Subdivision reports serving 200 people in Florida, per its EPA record.

Has Santa Fe Hills Subdivision had any water quality violations?

The EPA has 77 violations on file for Santa Fe Hills Subdivision, of which 7 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.