Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 2006-06-01 → 2006-06-30 |
| MCL | Health-based | Archived | 2006-06-01 → 2006-06-30 |
| MCL | Health-based | Archived | 2005-02-01 → 2005-02-28 |
| TT | Health-based | Resolved | 2004-07-01 |
| TT | Health-based | Resolved | 2004-07-01 |
| TT | Health-based | Resolved | 2004-07-01 |
| TT | Health-based | Resolved | 2004-07-01 |
| TT | Health-based | Resolved | 2004-07-01 |
| TT | Health-based | Resolved | 2004-07-01 |
| MCL | Health-based | Archived | 1992-08-01 → 1992-08-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 50.365 µg/L 63% of the EPA limit 80 µg/L
worst single sample: 52.83 µg/L | 32/32 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 19.615 µg/L 33% of the EPA limit 60 µg/L
worst single sample: 23.1 µg/L | 30/32 | SYR4 | 2012–2019 |
| Lead | 0.0021 mg/L 14% of the EPA limit 0.0150 mg/L | 17/17 | LCR | 2023 |
| Fluoride | 1200 µg/L 30% of the EPA limit 4000 µg/L | 13/14 | SYR4 | 2013–2017 |
| Barium | 86.9 µg/L 4.3% of the EPA limit 2000 µg/L
worst single sample: 89 µg/L | 7/7 | SYR4 | 2013–2017 |
| Copper | 25.4 µg/L 2% of the EPA limit 1300 µg/L
worst single sample: 26 µg/L | 7/7 | SYR4 | 2013–2017 |
| Nitrate | 70 µg/L 0.7% of the EPA limit 10000 µg/L | 6/48 | SYR4 | 2012–2019 |
| Xylenes, Total | 0.7470 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 0.7500 µg/L | 4/14 | SYR4 | 2013–2019 |
| Nitrite | 30 µg/L 3% of the EPA limit 1000 µg/L | 3/24 | SYR4 | 2012–2019 |
| Lithium | 19.3 µg/L No EPA limit set | 3/6 | UCMR-5 | 2024 |
| Cyanide | 5.1 µg/L 2.6% of the EPA limit 200 µg/L | 1/7 | SYR4 | 2013–2017 |
| Lead | 2.2 µg/L 15% of the EPA limit 15 µg/L | 1/7 | SYR4 | 2013–2017 |
82 contaminants tested, none detected
Utility contact
Frequently asked questions about Midway Water System, Inc.
Is Midway Water System, Inc. tap water safe to drink?
EPA monitoring detected 16 contaminants in Midway Water System, Inc.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Midway Water System, Inc.'s water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Lead, Fluoride, Barium, and others. The full list with the level and data source for each is above.
How many people does Midway Water System, Inc. serve?
Midway Water System, Inc. reports serving 21,196 people in Florida, per its EPA record.
Has Midway Water System, Inc. had any water quality violations?
The EPA has 24 violations on file for Midway Water System, Inc., of which 11 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.