← Florida

Tap water quality report

Tallahassee, City of

EPA monitoring tested this supplier for 100 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

100
contaminants tested
24
detected
200,480
people served
4
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Leon

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
13
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1997-10-01 → 1997-10-31
MCL Health-based Archived 1996-08-01 → 1996-08-31
MCL Health-based Resolved 1993-07-01 → 1993-07-31
MCL Health-based Resolved 1993-07-01 → 1993-07-31
MR Monitoring Unaddressed 2015-01-01
MR Monitoring Resolved 2013-08-01
MR Monitoring Resolved 2013-08-01
MR Monitoring Resolved 2013-08-01
MR Monitoring Resolved 1993-10-01 → 1993-10-31
MR Monitoring Resolved 1993-10-01 → 1993-10-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFHXS 0.0035 µg/L 2/50 2025
PFOS 0.0079 µg/L 2/50 2025
PFBS 0.0032 µg/L 1/50 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
620 µg/L 6.2%
of the EPA limit 10000 µg/L
worst single sample: 695 µg/L
428/432 SYR4 2012–2019
Tetrachloroethylene
1 µg/L 20%
of the EPA limit 5 µg/L
worst single sample: 1.91 µg/L
179/313 SYR4 2012–2019
TTHM
24.6085 µg/L 31%
of the EPA limit 80 µg/L
worst single sample: 40.84 µg/L
164/178 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
19.748 µg/L 33%
of the EPA limit 60 µg/L
worst single sample: 31.78 µg/L
125/179 SYR4 2012–2019
Fluoride
1100 µg/L 28%
of the EPA limit 4000 µg/L
worst single sample: 1310 µg/L
112/112 SYR4 2012–2019
Barium
13.1 µg/L 0.7%
of the EPA limit 2000 µg/L
worst single sample: 16.8 µg/L
56/56 SYR4 2012–2019
Copper
76.62 µg/L 5.9%
of the EPA limit 1300 µg/L
worst single sample: 219 µg/L
49/56 SYR4 2012–2019
Chromium
2.215 µg/L 2.2%
of the EPA limit 100 µg/L
worst single sample: 2.5 µg/L
38/56 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
2.665 pCi/L 18%
of the EPA limit 15 pCi/L
worst single sample: 6.6 pCi/L
28/31 SYR4 2012–2014
Lead
0.0014 mg/L 9.3%
of the EPA limit 0.0150 mg/L
16/16 LCR 2023
Trichloroethylene
0.4525 µg/L 9%
of the EPA limit 5 µg/L
worst single sample: 1 µg/L
16/284 SYR4 2012–2019
Oxamyl
0.3700 µg/L 0.2%
of the EPA limit 200 µg/L
15/57 SYR4 2012–2019
Diquat
0.4000 µg/L 2%
of the EPA limit 20 µg/L
14/57 SYR4 2012–2019
Glyphosate
5 µg/L 0.7%
of the EPA limit 700 µg/L
14/56 SYR4 2012–2019
Carbofuran
0.2500 µg/L 0.6%
of the EPA limit 40 µg/L
6/58 SYR4 2012–2019
Nitrite
10 µg/L 1%
of the EPA limit 1000 µg/L
4/216 SYR4 2012–2019
Cadmium
0.9600 µg/L 19%
of the EPA limit 5 µg/L
worst single sample: 1 µg/L
2/56 SYR4 2012–2019
Arsenic
2 µg/L 20%
of the EPA limit 10 µg/L
1/56 SYR4 2012–2019
Benzene
0.1800 µg/L 3.6%
of the EPA limit 5 µg/L
1/90 SYR4 2012–2019
Cyanide
3.4 µg/L 1.7%
of the EPA limit 200 µg/L
1/56 SYR4 2012–2019
cis-1,2-Dichloroethylene
0.1200 µg/L 0.2%
of the EPA limit 70 µg/L
1/89 SYR4 2012–2019
76 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzo(A)PyreneBeryllium, TotalChlorobenzeneCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNetfosaaNfdhaNmefosaaPfbaPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPfmbaPfmpaPFNAPFOAPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneVinyl ChlorideXylenes, TotalLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JENNIFER PORTER
Phone
850-891-5271

Frequently asked questions about Tallahassee, City of

Is Tallahassee, City of tap water safe to drink?

EPA monitoring detected 24 contaminants in Tallahassee, City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Tallahassee, City of's water?

EPA monitoring detected Nitrate, Tetrachloroethylene, TTHM, Total Haloacetic Acids (HAA5), Fluoride, and others. The full list with the level and data source for each is above.

How many people does Tallahassee, City of serve?

Tallahassee, City of reports serving 200,480 people in Florida, per its EPA record.

Has Tallahassee, City of had any water quality violations?

The EPA has 13 violations on file for Tallahassee, City of, of which 4 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.