← Florida

Tap water quality report

Leon Co. Regional System East

EPA monitoring tested this supplier for 71 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

71
contaminants tested
14
detected
1,984
people served
0
health-based violations
Water source
Ground water
Ownership
Mixed public/private
Counties served
Leon

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
9
violations on file
2
still open
ViolationTypeStatusPeriod
MR Monitoring Unaddressed 2022-01-01
MR Monitoring Unaddressed 2019-01-01
MR Monitoring Resolved 2016-01-01
MR Monitoring Resolved 2005-07-01 → 2005-09-30
MR Monitoring Resolved 2005-07-01 → 2005-09-30
MR Monitoring Resolved 2005-07-01 → 2005-09-30
MR Monitoring Resolved 2005-07-01 → 2005-09-30
MR Monitoring Resolved 2005-07-01 → 2005-09-30
MR Monitoring Resolved 2005-07-01 → 2005-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
500 µg/L 5%
of the EPA limit 10000 µg/L
worst single sample: 600 µg/L
48/48 SYR4 2012–2019
Fluoride
400 µg/L 10%
of the EPA limit 4000 µg/L
14/18 SYR4 2012–2018
Lead
0.00070 mg/L 4.7%
of the EPA limit 0.0150 mg/L
14/14 LCR 2024
Arsenic
0.7000 µg/L 7%
of the EPA limit 10 µg/L
9/9 SYR4 2012–2018
Barium
12 µg/L 0.6%
of the EPA limit 2000 µg/L
9/9 SYR4 2012–2018
Chromium
2.06 µg/L 2.1%
of the EPA limit 100 µg/L
worst single sample: 2.1 µg/L
9/9 SYR4 2012–2018
Copper
13.34 µg/L 1%
of the EPA limit 1300 µg/L
worst single sample: 16 µg/L
8/9 SYR4 2012–2018
Combined Uranium
0.8717 µg/L 2.9%
of the EPA limit 30 µg/L
worst single sample: 0.8940 µg/L
4/4 SYR4 2015–2018
Lead
1.47 µg/L 9.8%
of the EPA limit 15 µg/L
worst single sample: 1.5 µg/L
4/9 SYR4 2012–2018
TTHM
4.612 µg/L 5.8%
of the EPA limit 80 µg/L
worst single sample: 4.7 µg/L
3/10 SYR4 2012–2019
Antimony, Total
0.5000 µg/L 8.3%
of the EPA limit 6 µg/L
1/9 SYR4 2012–2018
Cyanide
3.1 µg/L 1.6%
of the EPA limit 200 µg/L
1/9 SYR4 2012–2018
Gross Alpha, Excl. Radon And U
1.8 pCi/L 12%
of the EPA limit 15 pCi/L
1/4 SYR4 2015–2018
Total Haloacetic Acids (HAA5)
5.22 µg/L 8.7%
of the EPA limit 60 µg/L
1/10 SYR4 2012–2019
57 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JOHN HALLAS
Phone
904-878-4414

Frequently asked questions about Leon Co. Regional System East

Is Leon Co. Regional System East tap water safe to drink?

EPA monitoring detected 14 contaminants in Leon Co. Regional System East's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Leon Co. Regional System East's water?

EPA monitoring detected Nitrate, Fluoride, Lead, Arsenic, Barium, and others. The full list with the level and data source for each is above.

How many people does Leon Co. Regional System East serve?

Leon Co. Regional System East reports serving 1,984 people in Florida, per its EPA record.

Has Leon Co. Regional System East had any water quality violations?

The EPA has 9 violations on file for Leon Co. Regional System East, of which 0 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.