← Delaware

Tap water quality report

Blades, Town of

EPA monitoring tested this supplier for 76 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

76
contaminants tested
22
detected
1,200
people served
3
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Sussex

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
20
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2007-01-01 → 2007-03-31
MCL Health-based Resolved 2007-01-01 → 2007-03-31
MCL Health-based Resolved 2007-01-01 → 2007-03-31
Other Monitoring Resolved 2022-03-31
Other Monitoring Resolved 2022-03-31
MON Monitoring Resolved 2021-05-01 → 2021-05-31
MON Monitoring Resolved 2021-05-01 → 2021-05-31
MON Monitoring Resolved 2021-05-01 → 2021-05-31
MON Monitoring Resolved 2021-05-01 → 2021-05-31
Other Monitoring Resolved 2017-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
4900 µg/L 49%
of the EPA limit 10000 µg/L
worst single sample: 5000 µg/L
176/176 SYR4 2012–2019
Fluoride
1288.37 µg/L 32%
of the EPA limit 4000 µg/L
worst single sample: 1830 µg/L
103/103 SYR4 2012–2019
Nitrate-Nitrite
4900 µg/L 49%
of the EPA limit 10000 µg/L
worst single sample: 5000 µg/L
87/87 SYR4 2012–2019
Copper
816.2 µg/L 63%
of the EPA limit 1300 µg/L
worst single sample: 1430 µg/L
33/34 SYR4 2012–2018
Lead
13.24 µg/L 88%
of the EPA limit 15 µg/L
worst single sample: 20.3 µg/L
23/34 SYR4 2012–2018
Chloroform
3.752 µg/L
No EPA limit set
worst single sample: 4.36 µg/L
9/9 SYR4 2014–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
9/9 LCR 2024
Bromodichloromethane
4.056 µg/L
No EPA limit set
worst single sample: 4.49 µg/L
8/9 SYR4 2014–2019
Dibromochloromethane
2.9195 µg/L
No EPA limit set
worst single sample: 3.07 µg/L
8/9 SYR4 2014–2019
TTHM
8.398 µg/L 10%
of the EPA limit 80 µg/L
worst single sample: 8.54 µg/L
5/5 SYR4 2014–2019
Barium
132.165 µg/L 6.6%
of the EPA limit 2000 µg/L
worst single sample: 132.3 µg/L
4/4 SYR4 2015
Chromium
1.655 µg/L 1.7%
of the EPA limit 100 µg/L
worst single sample: 1.7 µg/L
4/4 SYR4 2015
Dibromoacetic Acid
1.778 µg/L
No EPA limit set
worst single sample: 1.82 µg/L
3/4 SYR4 2014–2019
Dichloroacetic Acid
2.157 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
3/4 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
5.267 µg/L 8.8%
of the EPA limit 60 µg/L
worst single sample: 5.43 µg/L
3/4 SYR4 2014–2019
Bromoform
0.6145 µg/L
No EPA limit set
worst single sample: 0.6200 µg/L
2/9 SYR4 2014–2019
Combined Radium (-226 And -228)
2.175 pCi/L 43%
of the EPA limit 5 pCi/L
worst single sample: 2.2 pCi/L
2/2 SYR4 2013–2017
Trichloroacetic Acid
1.3695 µg/L
No EPA limit set
worst single sample: 1.41 µg/L
2/4 SYR4 2014–2019
Cyanide
116 µg/L 58%
of the EPA limit 200 µg/L
1/1 SYR4 2019
Di(2-ethylhexyl) Phthalate
0.3500 µg/L 5.8%
of the EPA limit 6 µg/L
1/3 SYR4 2012–2017
Monobromoacetic Acid
0.2000 µg/L
No EPA limit set
1/4 SYR4 2014–2019
Xylenes, Total
0.9600 µg/L 0%
of the EPA limit 10000 µg/L
1/9 SYR4 2014–2019
54 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GREGOR, CRYSTAL
Phone
302-629-7366
Email
[email protected]

Frequently asked questions about Blades, Town of

Is Blades, Town of tap water safe to drink?

EPA monitoring detected 22 contaminants in Blades, Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Blades, Town of's water?

EPA monitoring detected Nitrate, Fluoride, Nitrate-Nitrite, Copper, Lead, and others. The full list with the level and data source for each is above.

How many people does Blades, Town of serve?

Blades, Town of reports serving 1,200 people in Delaware, per its EPA record.

Has Blades, Town of had any water quality violations?

The EPA has 20 violations on file for Blades, Town of, of which 3 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.