Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2024-01-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2024-01-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2024-01-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2023-10-01 → 2024-09-30 |
| MCL | Health-based | Resolved | 2023-10-01 → 2024-09-30 |
| MCL | Health-based | Resolved | 2023-10-01 → 2024-09-30 |
| MCL | Health-based | Resolved | 2023-07-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2023-07-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2023-07-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2021-01-01 → 2021-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 6145 µg/L 61% of the EPA limit 10000 µg/L
worst single sample: 6400 µg/L | 38/38 | SYR4 | 2012–2019 |
| Copper | 1265 µg/L 97% of the EPA limit 1300 µg/L
worst single sample: 1600 µg/L | 28/28 | SYR4 | 2014–2019 |
| Combined Radium (-226 And -228) | 6.58 pCi/L 132% of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 7.3 pCi/L | 17/18 | SYR4 | 2014–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 16/16 | LCR | 2025 |
| Nitrate-Nitrite | 6000 µg/L 60% of the EPA limit 10000 µg/L | 11/11 | SYR4 | 2013–2019 |
| Lead | 71.6 µg/L 477% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 86 µg/L | 5/28 | SYR4 | 2014–2019 |
| Barium | 148.825 µg/L 7.4% of the EPA limit 2000 µg/L
worst single sample: 148.9 µg/L | 2/2 | SYR4 | 2016 |
62 contaminants tested, none detected
Utility contact
Frequently asked questions about Evergreen Post Acute
Is Evergreen Post Acute tap water safe to drink?
EPA monitoring detected 7 contaminants in Evergreen Post Acute's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Evergreen Post Acute's water?
EPA monitoring detected Nitrate, Copper, Combined Radium (-226 And -228), Lead, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.
How many people does Evergreen Post Acute serve?
Evergreen Post Acute reports serving 256 people in Delaware, per its EPA record.
Has Evergreen Post Acute had any water quality violations?
The EPA has 47 violations on file for Evergreen Post Acute, of which 14 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.