← Delaware

Tap water quality report

Cherry Creek Valley

EPA monitoring tested this supplier for 28 contaminants and detected 7. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

28
contaminants tested
7
detected
78
people served
38
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Sussex

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

38
health-based violations
75
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2023-04-14 → 2023-07-13
MCL Health-based Resolved 2023-04-14 → 2023-07-13
MCL Health-based Resolved 2023-04-14 → 2023-07-13
MCL Health-based Resolved 2023-04-14 → 2023-07-13
MCL Health-based Resolved 2022-11-22 → 2022-12-21
MCL Health-based Resolved 2022-11-22 → 2022-12-21
MCL Health-based Resolved 2022-11-22 → 2022-12-21

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
678 µg/L 52%
of the EPA limit 1300 µg/L
worst single sample: 1020 µg/L
37/37 SYR4 2012–2019
Lead
14.36 µg/L 96%
of the EPA limit 15 µg/L
worst single sample: 26.6 µg/L
32/37 SYR4 2012–2019
Nitrate
7900 µg/L 79%
of the EPA limit 10000 µg/L
20/20 SYR4 2012–2019
Lead
0.0069 mg/L 46%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
Nitrate-Nitrite
7867.42 µg/L 79%
of the EPA limit 10000 µg/L
worst single sample: 7900 µg/L
10/10 SYR4 2012–2019
Combined Radium (-226 And -228)
0.7805 pCi/L 16%
of the EPA limit 5 pCi/L
worst single sample: 0.7900 pCi/L
2/2 SYR4 2013–2019
Di(2-ethylhexyl) Phthalate
1.7 µg/L 28%
of the EPA limit 6 µg/L
1/2 SYR4 2012–2018
21 contaminants tested, none detected
1,2-DIBROMO-3-CHLOROPROPANEAtrazineBhc-GammaBenzo(A)PyreneCyanideCarbofuranChlordaneDi(2-ethylhexyl) AdipateEthylene DibromideEndrinFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorNitriteOxamylSimazineToxaphene

Utility contact

Contact
JOSEPH, MARY LOU
Phone
302-645-9655
Email
[email protected]

Frequently asked questions about Cherry Creek Valley

Is Cherry Creek Valley tap water safe to drink?

EPA monitoring detected 7 contaminants in Cherry Creek Valley's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Cherry Creek Valley's water?

EPA monitoring detected Copper, Lead, Nitrate, Lead, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Cherry Creek Valley serve?

Cherry Creek Valley reports serving 78 people in Delaware, per its EPA record.

Has Cherry Creek Valley had any water quality violations?

The EPA has 75 violations on file for Cherry Creek Valley, of which 38 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.