Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 1997-10-01 → 1997-12-31 |
| MCL | Health-based | Resolved | 1997-10-01 → 1997-12-31 |
| MCL | Health-based | Resolved | 1997-10-01 → 1997-12-31 |
| MCL | Health-based | Archived | 1997-10-01 → 1997-12-31 |
| MR | Monitoring | Resolved | 2021-10-01 |
| MR | Monitoring | Resolved | 2021-10-01 |
| MR | Monitoring | Resolved | 2021-10-01 |
| MON | Monitoring | Resolved | 2016-05-01 → 2016-05-31 |
| MON | Monitoring | Resolved | 2016-05-01 → 2016-05-31 |
| MON | Monitoring | Resolved | 2016-05-01 → 2016-05-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Fluoride | 1238.5 µg/L 31% of the EPA limit 4000 µg/L
worst single sample: 2110 µg/L | 78/103 | SYR4 | 2012–2019 |
| Copper | 61.495 µg/L 4.7% of the EPA limit 1300 µg/L
worst single sample: 330 µg/L | 24/31 | SYR4 | 2015–2018 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2025 |
| Chloroform | 12.8685 µg/L No EPA limit set
worst single sample: 13.25 µg/L | 8/8 | SYR4 | 2014–2019 |
| TTHM | 15.965 µg/L 20% of the EPA limit 80 µg/L
worst single sample: 16.02 µg/L | 6/6 | SYR4 | 2014–2019 |
| Bromodichloromethane | 3.046 µg/L No EPA limit set
worst single sample: 3.17 µg/L | 5/8 | SYR4 | 2014–2019 |
| Dichloroacetic Acid | 5.3284 µg/L No EPA limit set
worst single sample: 5.683 µg/L | 5/6 | SYR4 | 2014–2019 |
| Lead | 6.274 µg/L 42% of the EPA limit 15 µg/L
worst single sample: 6.43 µg/L | 5/31 | SYR4 | 2015–2018 |
| Total Haloacetic Acids (HAA5) | 10.3826 µg/L 17% of the EPA limit 60 µg/L
worst single sample: 10.962 µg/L | 5/6 | SYR4 | 2014–2019 |
| Trichloroacetic Acid | 5.1104 µg/L No EPA limit set
worst single sample: 5.279 µg/L | 4/6 | SYR4 | 2014–2019 |
| Dibromochloromethane | 0.6815 µg/L No EPA limit set
worst single sample: 0.6900 µg/L | 2/8 | SYR4 | 2014–2019 |
| Bromoform | 0.8300 µg/L No EPA limit set | 1/8 | SYR4 | 2014–2019 |
| Combined Radium (-226 And -228) | 0.3000 pCi/L 6% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2013 |
62 contaminants tested, none detected
Utility contact
Frequently asked questions about Harrington Water Department
Is Harrington Water Department tap water safe to drink?
EPA monitoring detected 13 contaminants in Harrington Water Department's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Harrington Water Department's water?
EPA monitoring detected Fluoride, Copper, Lead, Chloroform, TTHM, and others. The full list with the level and data source for each is above.
How many people does Harrington Water Department serve?
Harrington Water Department reports serving 3,562 people in Delaware, per its EPA record.
Has Harrington Water Department had any water quality violations?
The EPA has 32 violations on file for Harrington Water Department, of which 4 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.