Tap water quality report

University of Connecticut - Main Campus

EPA monitoring tested this supplier for 110 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
21
detected
27,199
people served
12
health-based violations
Water source
SWP
Ownership
State government
Counties served
Tolland

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

12
health-based violations
64
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2003-09-01 → 2003-09-30
MCL Health-based Resolved 2003-09-01 → 2003-09-30
MCL Health-based Resolved 2003-09-01 → 2003-09-30
MCL Health-based Resolved 2003-09-01 → 2003-09-30
MCL Health-based Resolved 2001-10-01 → 2001-10-31
MCL Health-based Resolved 2001-10-01 → 2001-10-31
MCL Health-based Resolved 2001-10-01 → 2001-10-31
MCL Health-based Resolved 2001-10-01 → 2001-10-31
MCL Health-based Resolved 2000-01-01 → 2002-12-31
MCL Health-based Resolved 2000-01-01 → 2002-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFOS 0.0050 µg/L 2/6 2024
Pfba 0.0050 µg/L 1/6 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
7.135 µg/L
No EPA limit set
worst single sample: 9.6 µg/L
134/152 SYR4 2012–2019
Chloroform
16.72 µg/L
No EPA limit set
worst single sample: 27 µg/L
133/152 SYR4 2012–2019
Dibromochloromethane
5.58 µg/L
No EPA limit set
worst single sample: 7.3 µg/L
133/152 SYR4 2012–2019
TTHM
26.888 µg/L 34%
of the EPA limit 80 µg/L
worst single sample: 38.3 µg/L
130/132 SYR4 2012–2019
Bromoform
2.23 µg/L
No EPA limit set
worst single sample: 3.5 µg/L
115/152 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
7.21 µg/L 12%
of the EPA limit 60 µg/L
worst single sample: 12.2 µg/L
87/131 SYR4 2012–2019
Dichloroacetic Acid
3.66 µg/L
No EPA limit set
worst single sample: 6.9 µg/L
69/131 SYR4 2012–2019
Copper
302.3 µg/L 23%
of the EPA limit 1300 µg/L
worst single sample: 480 µg/L
60/60 SYR4 2014–2017
Dibromoacetic Acid
1.735 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
54/131 SYR4 2012–2019
Trichloroacetic Acid
5.42 µg/L
No EPA limit set
worst single sample: 9.5 µg/L
54/131 SYR4 2012–2019
Nitrate
866.7 µg/L 8.7%
of the EPA limit 10000 µg/L
worst single sample: 899 µg/L
38/38 SYR4 2012–2019
Lead
16.5 µg/L 110%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 27 µg/L
31/60 SYR4 2014–2017
Nitrate-Nitrite
864.8 µg/L 8.6%
of the EPA limit 10000 µg/L
worst single sample: 899 µg/L
19/19 SYR4 2012–2019
Lead
0.00070 mg/L 4.7%
of the EPA limit 0.0150 mg/L
10/10 LCR 2023
Barium
22.5 µg/L 1.1%
of the EPA limit 2000 µg/L
worst single sample: 25 µg/L
6/6 SYR4 2013–2019
Fluoride
716.5 µg/L 18%
of the EPA limit 4000 µg/L
worst single sample: 740 µg/L
2/6 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
5.045 pCi/L 34%
of the EPA limit 15 pCi/L
worst single sample: 5.1 pCi/L
2/7 SYR4 2013–2019
Combined Radium (-226 And -228)
1.29 pCi/L 26%
of the EPA limit 5 pCi/L
1/7 SYR4 2013–2019
Monochloroacetic Acid
0.8000 µg/L
No EPA limit set
1/131 SYR4 2012–2019
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NOLAN, STANLEY
Phone
860-486-3208
Email
[email protected]

Frequently asked questions about University of Connecticut - Main Campus

Is University of Connecticut - Main Campus tap water safe to drink?

EPA monitoring detected 21 contaminants in University of Connecticut - Main Campus's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in University of Connecticut - Main Campus's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Bromoform, and others. The full list with the level and data source for each is above.

How many people does University of Connecticut - Main Campus serve?

University of Connecticut - Main Campus reports serving 27,199 people in Connecticut, per its EPA record.

Has University of Connecticut - Main Campus had any water quality violations?

The EPA has 64 violations on file for University of Connecticut - Main Campus, of which 12 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.