← Connecticut

Tap water quality report

Aquarion-Eastern Fairfield County

EPA monitoring tested this supplier for 109 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
25
detected
351,756
people served
5
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Fairfield

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
585
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 1992-01-01
TT Health-based Resolved 1992-01-01
TT Health-based Resolved 1992-01-01
TT Health-based Archived 1992-01-01 → 1998-10-01
TT Health-based Archived 1992-01-01 → 1998-10-01
MR Monitoring Archived 2021-01-01 → 2023-12-31
MR Monitoring Archived 2021-01-01 → 2023-12-31
MR Monitoring Archived 2021-01-01 → 2023-12-31
MR Monitoring Archived 2021-01-01 → 2023-12-31
MR Monitoring Archived 2021-01-01 → 2023-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0076 µg/L 3/14 2024
PFOA 0.0109 µg/L 3/14 2024
Pfhxa 0.0074 µg/L 2/14 2024
PFOS 0.0066 µg/L 2/14 2024
Pfpea 0.0067 µg/L 2/14 2024
PFBS 0.0041 µg/L 1/14 2024
Pfhpa 0.0039 µg/L 1/14 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
16 µg/L
No EPA limit set
worst single sample: 19 µg/L
417/426 SYR4 2012–2019
Dibromochloromethane
3 µg/L
No EPA limit set
417/426 SYR4 2012–2019
Chloroform
63 µg/L
No EPA limit set
worst single sample: 79 µg/L
411/426 SYR4 2012–2019
TTHM
80.7 µg/L 101%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 101 µg/L
384/384 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
53.9 µg/L 90%
of the EPA limit 60 µg/L
worst single sample: 75 µg/L
383/384 SYR4 2012–2019
Trichloroacetic Acid
29 µg/L
No EPA limit set
worst single sample: 38 µg/L
382/384 SYR4 2012–2019
Dichloroacetic Acid
24 µg/L
No EPA limit set
worst single sample: 36 µg/L
380/384 SYR4 2012–2019
Monochloroacetic Acid
2 µg/L
No EPA limit set
worst single sample: 3 µg/L
314/384 SYR4 2012–2019
Dibromoacetic Acid
1 µg/L
No EPA limit set
167/384 SYR4 2012–2019
Copper
261 µg/L 20%
of the EPA limit 1300 µg/L
worst single sample: 360 µg/L
159/205 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
98/98 LCR 2026
Nitrate
1339 µg/L 13%
of the EPA limit 10000 µg/L
worst single sample: 1560 µg/L
82/82 SYR4 2012–2019
Nitrate-Nitrite
1285 µg/L 13%
of the EPA limit 10000 µg/L
worst single sample: 1560 µg/L
65/65 SYR4 2012–2019
Barium
48.9 µg/L 2.4%
of the EPA limit 2000 µg/L
worst single sample: 55 µg/L
52/52 SYR4 2012–2019
Fluoride
916 µg/L 23%
of the EPA limit 4000 µg/L
worst single sample: 1080 µg/L
52/52 SYR4 2012–2019
Lead
42.65 µg/L 284%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 668 µg/L
44/205 SYR4 2012–2019
Monobromoacetic Acid
1 µg/L
No EPA limit set
17/384 SYR4 2012–2019
Bromoform
0.5950 µg/L
No EPA limit set
worst single sample: 0.6000 µg/L
2/426 SYR4 2012–2019
84 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfdaPfdoaPfeesaPfhpsPFHXSPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ULRICH, ROBERT J.
Phone
203-926-4320
Email
[email protected]

Frequently asked questions about Aquarion-Eastern Fairfield County

Is Aquarion-Eastern Fairfield County tap water safe to drink?

EPA monitoring detected 25 contaminants in Aquarion-Eastern Fairfield County's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Aquarion-Eastern Fairfield County's water?

EPA monitoring detected Bromodichloromethane, Dibromochloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Aquarion-Eastern Fairfield County serve?

Aquarion-Eastern Fairfield County reports serving 351,756 people in Connecticut, per its EPA record.

Has Aquarion-Eastern Fairfield County had any water quality violations?

The EPA has 585 violations on file for Aquarion-Eastern Fairfield County, of which 5 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.