Tap water quality report

Ctwc - Pompey Hollow Division

EPA monitoring tested this supplier for 73 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

73
contaminants tested
9
detected
32
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Windham

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
4
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2005-08-10
Other Monitoring Resolved 2005-08-10
Other Monitoring Resolved 2005-07-01
Other Monitoring Resolved 2005-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
142.8 µg/L 11%
of the EPA limit 1300 µg/L
worst single sample: 234 µg/L
17/17 SYR4 2013–2017
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2023
Nitrate
30 µg/L 0.3%
of the EPA limit 10000 µg/L
6/18 SYR4 2012–2019
Barium
6 µg/L 0.3%
of the EPA limit 2000 µg/L
3/3 SYR4 2013–2019
Fluoride
238 µg/L 5.9%
of the EPA limit 4000 µg/L
worst single sample: 240 µg/L
3/3 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
5.004 pCi/L 33%
of the EPA limit 15 pCi/L
worst single sample: 5.15 pCi/L
3/3 SYR4 2013–2019
Lead
6.11 µg/L 41%
of the EPA limit 15 µg/L
worst single sample: 6.3 µg/L
3/17 SYR4 2013–2017
Nitrate-Nitrite
29 µg/L 0.3%
of the EPA limit 10000 µg/L
worst single sample: 30 µg/L
3/9 SYR4 2012–2019
Combined Uranium
5.0775 µg/L 17%
of the EPA limit 30 µg/L
worst single sample: 5.15 µg/L
2/2 SYR4 2013–2019
64 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LOWRY, PAUL C.
Phone
860-944-9655
Email
[email protected]

Frequently asked questions about Ctwc - Pompey Hollow Division

Is Ctwc - Pompey Hollow Division tap water safe to drink?

EPA monitoring detected 9 contaminants in Ctwc - Pompey Hollow Division's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ctwc - Pompey Hollow Division's water?

EPA monitoring detected Copper, Lead, Nitrate, Barium, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Ctwc - Pompey Hollow Division serve?

Ctwc - Pompey Hollow Division reports serving 32 people in Connecticut, per its EPA record.

Has Ctwc - Pompey Hollow Division had any water quality violations?

The EPA has 4 violations on file for Ctwc - Pompey Hollow Division, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.