Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2024-01-01 → 2024-12-31 |
| MR | Monitoring | Resolved | 2024-01-01 → 2024-12-31 |
| MR | Monitoring | Resolved | 2024-01-01 → 2024-12-31 |
| Other | Monitoring | Resolved | 2021-11-08 |
| Other | Monitoring | Resolved | 2021-11-08 |
| Other | Monitoring | Resolved | 2021-07-08 |
| Other | Monitoring | Resolved | 2021-07-08 |
| Other | Monitoring | Resolved | 2020-11-20 |
| Other | Monitoring | Resolved | 2020-11-20 |
| Other | Monitoring | Resolved | 2020-11-20 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 2100 µg/L 21% of the EPA limit 10000 µg/L | 18/18 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 9/9 | LCR | 2023 |
| Barium | 80.25 µg/L 4% of the EPA limit 2000 µg/L
worst single sample: 81 µg/L | 4/4 | SYR4 | 2012–2019 |
| Combined Uranium | 2.48 µg/L 8.3% of the EPA limit 30 µg/L
worst single sample: 2.5 µg/L | 3/3 | SYR4 | 2012–2019 |
| Bromodichloromethane | 14.76 µg/L No EPA limit set
worst single sample: 15.5 µg/L | 2/3 | SYR4 | 2012–2013 |
| Combined Radium (-226 And -228) | 0.3950 pCi/L 7.9% of the EPA limit 5 pCi/L
worst single sample: 0.4000 pCi/L | 2/2 | SYR4 | 2012 |
| Dibromochloromethane | 1.76 µg/L No EPA limit set
worst single sample: 1.8 µg/L | 2/3 | SYR4 | 2012–2013 |
| Gross Alpha, Excl. Radon And U | 1.04995 pCi/L 7% of the EPA limit 15 pCi/L
worst single sample: 1.06 pCi/L | 2/2 | SYR4 | 2012–2019 |
| TTHM | 2.98 µg/L 3.7% of the EPA limit 80 µg/L
worst single sample: 3.1 µg/L | 2/3 | SYR4 | 2012–2017 |
| Bromoform | 0.6000 µg/L No EPA limit set | 1/3 | SYR4 | 2012–2013 |
| Chloroform | 90.6 µg/L No EPA limit set | 1/3 | SYR4 | 2012–2013 |
| Fluoride | 110 µg/L 2.8% of the EPA limit 4000 µg/L | 1/4 | SYR4 | 2012–2019 |
| Selenium | 1 µg/L 2% of the EPA limit 50 µg/L | 1/4 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 2.12 µg/L 3.5% of the EPA limit 60 µg/L | 1/3 | SYR4 | 2012–2017 |
57 contaminants tested, none detected
Utility contact
Frequently asked questions about Timber Creek Wd
Is Timber Creek Wd tap water safe to drink?
EPA monitoring detected 14 contaminants in Timber Creek Wd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Timber Creek Wd's water?
EPA monitoring detected Nitrate, Lead, Barium, Combined Uranium, Bromodichloromethane, and others. The full list with the level and data source for each is above.
How many people does Timber Creek Wd serve?
Timber Creek Wd reports serving 312 people in Colorado, per its EPA record.
Has Timber Creek Wd had any water quality violations?
The EPA has 391 violations on file for Timber Creek Wd, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.