← Colorado

Tap water quality report

Erie Town of

EPA monitoring tested this supplier for 107 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

107
contaminants tested
15
detected
47,444
people served
3
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Boulder

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
114
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2005-04-01 → 2005-06-30
MCL Health-based Resolved 2005-04-01 → 2005-06-30
MCL Health-based Resolved 2005-04-01 → 2005-06-30
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2020-01-01 → 2022-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
67.5 µg/L 84%
of the EPA limit 80 µg/L
worst single sample: 87.5 µg/L
132/132 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
41.53 µg/L 69%
of the EPA limit 60 µg/L
worst single sample: 50.1 µg/L
128/128 SYR4 2012–2019
Bromodichloromethane
7.8 µg/L
No EPA limit set
worst single sample: 9.7 µg/L
81/81 SYR4 2012–2019
Chloroform
62.14 µg/L
No EPA limit set
worst single sample: 69.5 µg/L
80/80 SYR4 2012–2019
Dichloroacetic Acid
17.975 µg/L
No EPA limit set
worst single sample: 20.9 µg/L
76/76 SYR4 2015–2019
Trichloroacetic Acid
19.245 µg/L
No EPA limit set
worst single sample: 22.9 µg/L
72/76 SYR4 2015–2019
Monochloroacetic Acid
10.89 µg/L
No EPA limit set
worst single sample: 14.4 µg/L
32/76 SYR4 2015–2019
Fluoride
755 µg/L 19%
of the EPA limit 4000 µg/L
worst single sample: 940 µg/L
31/31 SYR4 2012–2019
Lead
0.0026 mg/L 17%
of the EPA limit 0.0150 mg/L
22/22 LCR 2025
Dibromochloromethane
1.74 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
17/81 SYR4 2012–2019
Nitrate
83 µg/L 0.8%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Nitrate-Nitrite
69.25 µg/L 0.7%
of the EPA limit 10000 µg/L
worst single sample: 71 µg/L
2/2 SYR4 2012–2019
Barium
12 µg/L 0.6%
of the EPA limit 2000 µg/L
1/1 SYR4 2019
Combined Radium (-226 And -228)
1.2 pCi/L 24%
of the EPA limit 5 pCi/L
1/1 SYR4 2019
Dibromoacetic Acid
1 µg/L
No EPA limit set
1/76 SYR4 2015–2019
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FESSENDEN, TODD
Phone
303-926-2895
Email
[email protected]

Frequently asked questions about Erie Town of

Is Erie Town of tap water safe to drink?

EPA monitoring detected 15 contaminants in Erie Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Erie Town of's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Erie Town of serve?

Erie Town of reports serving 47,444 people in Colorado, per its EPA record.

Has Erie Town of had any water quality violations?

The EPA has 114 violations on file for Erie Town of, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.