← Colorado

Tap water quality report

Teller County Wsd

EPA monitoring tested this supplier for 79 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
18
detected
600
people served
39
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Teller

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

39
health-based violations
305
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-07-01 → 2022-09-30
MCL Health-based Resolved 2022-07-01 → 2022-09-30
MCL Health-based Resolved 2022-07-01 → 2022-09-30
MCL Health-based Resolved 2022-07-01 → 2022-09-30
MCL Health-based Resolved 2022-07-01 → 2022-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Ethylene Dibromide
0.0890 µg/L 178%
of the EPA limit, at the 95th percentile of samples — 0.0500 µg/L
worst single sample: 0.1000 µg/L
43/102 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
17/17 LCR 2025
Nitrate
3800 µg/L 38%
of the EPA limit 10000 µg/L
16/20 SYR4 2012–2019
Copper
705.6 µg/L 54%
of the EPA limit 1300 µg/L
worst single sample: 729 µg/L
10/10 SYR4 2015
TTHM
4.39 µg/L 5.5%
of the EPA limit 80 µg/L
worst single sample: 4.6 µg/L
8/8 SYR4 2013–2019
Chloroform
1.95 µg/L
No EPA limit set
worst single sample: 2 µg/L
6/6 SYR4 2012–2019
Dibromochloromethane
1.25 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
6/6 SYR4 2012–2019
Lead
3.6 µg/L 24%
of the EPA limit 15 µg/L
worst single sample: 4 µg/L
5/10 SYR4 2015
Bromodichloromethane
0.9850 µg/L
No EPA limit set
worst single sample: 1 µg/L
4/6 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
3.433 µg/L 5.7%
of the EPA limit 60 µg/L
worst single sample: 3.53 µg/L
3/8 SYR4 2013–2019
Barium
193.05 µg/L 9.7%
of the EPA limit 2000 µg/L
worst single sample: 195 µg/L
2/2 SYR4 2015–2018
Bromoform
0.7950 µg/L
No EPA limit set
worst single sample: 0.8000 µg/L
2/6 SYR4 2012–2019
Combined Radium (-226 And -228)
4.78 pCi/L 96%
of the EPA limit 5 pCi/L
worst single sample: 4.8 pCi/L
2/2 SYR4 2014–2017
Fluoride
1897 µg/L 47%
of the EPA limit 4000 µg/L
worst single sample: 1920 µg/L
2/2 SYR4 2015–2018
Gross Alpha, Excl. Radon And U
9.64 pCi/L 64%
of the EPA limit 15 pCi/L
worst single sample: 10 pCi/L
2/2 SYR4 2012–2014
1,2-DIBROMO-3-CHLOROPROPANE
0.0200 µg/L 10%
of the EPA limit 0.2000 µg/L
1/93 SYR4 2012–2019
Nitrate-Nitrite
2600 µg/L 26%
of the EPA limit 10000 µg/L
1/3 SYR4 2012–2014
Selenium
1 µg/L 2%
of the EPA limit 50 µg/L
1/2 SYR4 2015–2018
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FRITZ, BARBARA
Phone
719-687-0761
Email
[email protected]

Frequently asked questions about Teller County Wsd

Is Teller County Wsd tap water safe to drink?

EPA monitoring detected 18 contaminants in Teller County Wsd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Teller County Wsd's water?

EPA monitoring detected Ethylene Dibromide, Lead, Nitrate, Copper, TTHM, and others. The full list with the level and data source for each is above.

How many people does Teller County Wsd serve?

Teller County Wsd reports serving 600 people in Colorado, per its EPA record.

Has Teller County Wsd had any water quality violations?

The EPA has 305 violations on file for Teller County Wsd, of which 39 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.