Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2022-08-01 → 2022-08-31 |
| TT | Health-based | Resolved | 2022-08-01 → 2022-08-31 |
| TT | Health-based | Resolved | 2022-08-01 → 2022-08-31 |
| TT | Health-based | Resolved | 2022-08-01 → 2022-08-31 |
| TT | Health-based | Resolved | 2022-07-01 → 2022-07-31 |
| TT | Health-based | Resolved | 2022-07-01 → 2022-07-31 |
| TT | Health-based | Resolved | 2022-07-01 → 2022-07-31 |
| TT | Health-based | Resolved | 2022-07-01 → 2022-07-31 |
| TT | Health-based | Resolved | 2004-12-01 → 2004-12-31 |
| TT | Health-based | Resolved | 2004-12-01 → 2004-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 71.725 µg/L 90% of the EPA limit 80 µg/L
worst single sample: 82.2 µg/L | 76/76 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 56.08 µg/L 93% of the EPA limit 60 µg/L
worst single sample: 71.2 µg/L | 73/73 | SYR4 | 2012–2019 |
| Bromodichloromethane | 10.045 µg/L No EPA limit set
worst single sample: 12.4 µg/L | 58/58 | SYR4 | 2012–2019 |
| Chloroform | 62.105 µg/L No EPA limit set
worst single sample: 67.5 µg/L | 58/58 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 23.64 µg/L No EPA limit set
worst single sample: 25.6 µg/L | 54/54 | SYR4 | 2015–2019 |
| Trichloroacetic Acid | 29.87 µg/L No EPA limit set
worst single sample: 31.8 µg/L | 54/54 | SYR4 | 2015–2019 |
| Dibromochloromethane | 1.745 µg/L No EPA limit set
worst single sample: 2.3 µg/L | 52/58 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 2.505 µg/L No EPA limit set
worst single sample: 2.6 µg/L | 20/54 | SYR4 | 2015–2019 |
| Lead | 0.0020 mg/L 13% of the EPA limit 0.0150 mg/L | 19/19 | LCR | 2025 |
| Nitrate | 200 µg/L 2% of the EPA limit 10000 µg/L | 18/18 | SYR4 | 2012–2019 |
| Fluoride | 840 µg/L 21% of the EPA limit 4000 µg/L
worst single sample: 880 µg/L | 17/18 | SYR4 | 2012–2019 |
| Barium | 92 µg/L 4.6% of the EPA limit 2000 µg/L | 1/1 | SYR4 | 2015 |
| Combined Radium (-226 And -228) | 0.1000 pCi/L 2% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2016 |
| Combined Uranium | 1.1 µg/L 3.7% of the EPA limit 30 µg/L | 1/1 | SYR4 | 2016 |
| Hexachlorobenzene | 0.0097 µg/L 1% of the EPA limit 1 µg/L | 1/7 | SYR4 | 2013–2017 |
| Monobromoacetic Acid | 2.7 µg/L No EPA limit set | 1/54 | SYR4 | 2015–2019 |
| Nitrate-Nitrite | 200 µg/L 2% of the EPA limit 10000 µg/L | 1/1 | SYR4 | 2016 |
90 contaminants tested, none detected
Utility contact
Frequently asked questions about Breckenridge Town of
Is Breckenridge Town of tap water safe to drink?
EPA monitoring detected 17 contaminants in Breckenridge Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Breckenridge Town of's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Breckenridge Town of serve?
Breckenridge Town of reports serving 28,315 people in Colorado, per its EPA record.
Has Breckenridge Town of had any water quality violations?
The EPA has 219 violations on file for Breckenridge Town of, of which 14 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.