← Colorado

Tap water quality report

Rye Town of

EPA monitoring tested this supplier for 77 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
17
detected
745
people served
337
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Pueblo

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

337
health-based violations
864
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2025-01-01 → 2025-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
199.57 µg/L 249%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 241.7 µg/L
30/30 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
274.169 µg/L 457%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 322 µg/L
30/30 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
26/26 LCR 2025
Bromodichloromethane
4.005 µg/L
No EPA limit set
worst single sample: 4.2 µg/L
14/14 SYR4 2012–2019
Chloroform
188.705 µg/L
No EPA limit set
worst single sample: 192.8 µg/L
14/14 SYR4 2012–2019
Dichloroacetic Acid
91.045 µg/L
No EPA limit set
worst single sample: 109.8 µg/L
12/12 SYR4 2014–2019
Trichloroacetic Acid
170.89 µg/L
No EPA limit set
worst single sample: 175.4 µg/L
12/12 SYR4 2014–2019
Nitrate
100 µg/L 1%
of the EPA limit 10000 µg/L
10/16 SYR4 2012–2019
Barium
23.65 µg/L 1.2%
of the EPA limit 2000 µg/L
worst single sample: 24 µg/L
8/8 SYR4 2012–2019
Monochloroacetic Acid
6.66 µg/L
No EPA limit set
worst single sample: 7.7 µg/L
5/12 SYR4 2014–2019
Nitrate-Nitrite
100 µg/L 1%
of the EPA limit 10000 µg/L
2/3 SYR4 2012–2015
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/8 SYR4 2012–2019
Combined Uranium
0.8000 µg/L 2.7%
of the EPA limit 30 µg/L
1/1 SYR4 2013
Ethylbenzene
0.7000 µg/L 0.1%
of the EPA limit 700 µg/L
1/14 SYR4 2012–2019
Fluoride
90 µg/L 2.3%
of the EPA limit 4000 µg/L
1/8 SYR4 2012–2019
Selenium
1 µg/L 2%
of the EPA limit 50 µg/L
1/8 SYR4 2012–2019
Xylenes, Total
4 µg/L 0%
of the EPA limit 10000 µg/L
1/14 SYR4 2012–2019
60 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RAHL, MARTY
Phone
719-569-0354
Email
[email protected]

Frequently asked questions about Rye Town of

Is Rye Town of tap water safe to drink?

EPA monitoring detected 17 contaminants in Rye Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Rye Town of's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Lead, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Rye Town of serve?

Rye Town of reports serving 745 people in Colorado, per its EPA record.

Has Rye Town of had any water quality violations?

The EPA has 864 violations on file for Rye Town of, of which 337 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.